EEWORLDEEWORLDEEWORLD

Part Number

Search

U5395-000016-3.5BA

Description
Peizoresistive Sensor, Absolute, 0Psi Min, 50Psi Max, 0.1%, 0.5-4.5V, Cylindrical
CategoryThe sensor    Sensor/transducer   
File Size319KB,8 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric View All

U5395-000016-3.5BA Overview

Peizoresistive Sensor, Absolute, 0Psi Min, 50Psi Max, 0.1%, 0.5-4.5V, Cylindrical

U5395-000016-3.5BA Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerTE Connectivity
Reach Compliance Codeunknown
Maximum accuracy(%)0.1%
Other featuresPort Height = 9.9 MM
body height58.6 mm
Body length or diameter24 mm
Maximum working current5 mA
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Output range0.5-4.5V
Output typeVOLTAGE OUTPUT
Package Shape/FormCYLINDRICAL
port type1/8-27 NPT
Maximum pressure range50 Psi
Minimum pressure range
Pressure sensing modeABSOLUTE
Response time2000 µs
Sensor/Transducer TypePRESSURE SENSOR,PIEZORESISTIVE
Maximum supply voltage30 V
Minimum supply voltage5 V
Termination typeCONNECTOR
Base Number Matches1
U5300
Industrial Pressure Transducer
SPECIFICATIONS
Superior Accuracy and Total Error Band
Instrument Grade and Compact
Variety of Pressure Ports and Electrical Configurations
Optional Stainless Steel Snubber
CE Compliant and Weatherproof
UL Certified
Gage, Sealed, Absolute, Compound
Expedite Configurations Available (10 Days)
FEATURES
Heavy Industrial CE Approval
10 V/m EMI Protection
Reverse Polarity Protection on Input
Short Circuit Protection on Output
±0.1% Accuracy
±0.5% Total Error Band
Compact Outline
-40°C to +125°C Operating Temperature
Weatherproof
The instrument grade U5300
pressure transducers from the UltraStable line
of MEAS, with their modular design, offer maximum flexibility for different
configurations. This latest series features superior accuracy and total error
band for demanding commercial and heavy industrial applications. This
series is suitable for measurement of liquid or gas pressure, even for difficult
media such as contaminated water, steam, and mildly corrosive fluids.
The wetted material is made of 316L stainless steel and the transducer’s
durability is excellent with no O-rings or organics exposed to the pressure
media. The U5300 is weatherproof and exceeds the latest heavy industrial
CE requirements including surge protection. The circuit is protected from
reverse wiring at input and short circuit at output.
This product is geared to the OEM customer for low to mid volumes. MEAS
stands ready to provide a custom design of the U5300 where the volume and
application warrants. Additional configurations not listed are either available
or possible. Please inquire for further information.
APPLICATIONS
Military/Aerospace Test Stands
Automotive Test Stands
Calibration Equipment
High Accuracy Applications
Stationary Motor Fuel Control
High End Industrial Machinery
SENSOR SOLUTIONS
///U5300
07/2018
Page 1
[Project source code] [Modelsim FAQ] Port 'xxxx' not found in the connected module
This article and design code were written by FPGA enthusiast Xiao Meige. Without the author's permission, this article is only allowed to be copied and reproduced on online forums, and the original au...
小梅哥 Altera SoC
An error in the CC3200 Out of Box Application example
When I first saw the temperature in the Out of Box example, I wondered if the temperature sensor was broken. Then I thought that the temperature unit might be Fahrenheit. For people who are used to us...
littleshrimp RF/Wirelessly
Question: How to connect a 1UF/400V capacitor in a 220V AC circuit?
I would like to ask: If a 1UF/400V capacitor is connected in parallel to a 220V AC circuit and a 3.6K/15W resistor is connected in parallel to a 220V AC circuit, are their power consumption (watt-hour...
book1 Test/Measurement
DSP Learning (2) Overview of TMS320VC5402
Chapter 2 Overview of TMS320VC5402The most widely used DSPs in the industry are TI's TMS320 series DSPs. TMS320C5402 is a highly cost-effective fixed-point digital signal processor DSPs launched by TI...
Aguilera DSP and ARM Processors
How to isolate interference in the line
If the microcontroller serial port and the driver module are placed on the same wire and the load is working, it will burn the microcontroller. What is the best communication method for this serial po...
tangwei8802429 Analog electronics
Several ways of current sampling
Several ways of current sampling1. Use sampling resistors directly and ADC to measure the voltage drop on the resistor without processing circuits such as op amps. 2. Use sampling resistors and ADC to...
QWE4562009 Discrete Device

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号