EEWORLDEEWORLDEEWORLD

Part Number

Search

HGN-375C03S-48-1MM2

Description
Mains Power Connector, 3A, 125/250VAC, Male, Solder Terminal, Socket
CategoryThe connector    The connector   
File Size485KB,3 Pages
ManufacturerPower Dynamics, Inc.
Websitehttp://www.powerdynamics.com/
Environmental Compliance
Download Datasheet Parametric View All

HGN-375C03S-48-1MM2 Overview

Mains Power Connector, 3A, 125/250VAC, Male, Solder Terminal, Socket

HGN-375C03S-48-1MM2 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerPower Dynamics, Inc.
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC 60320; UL; VDE
Body/casing typeSOCKET
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings3A, 125/250VAC
Manufacturer's serial numberHGN-375
Installation typePANEL
OptionsGENERAL PURPOSE
Termination typeSOLDER
Total number of contacts3
Base Number Matches1
HGN-375(A, B, C)
FUSED WITH ON/OFF SWITCH, IEC 60320 POWER INLET
SOCKET WITH FUSE/S (5X20MM)
MECHANICAL DIMENSIONS
(Unit: mm)
CASE A
49.83
60.71
55.04
65.4
Use only with a 250V Fuse
Employer uniqement avec
un fusible de 250V
60.0
O
32.45
-
40 + 0.2
3.5
49.37
2x M3
61.5
CASE B
FEATURES
2x 3.3
The HGN-375(A, B, C) series offers filters in three different
package styles - Flange mount (sides), Flange mount (top/
bottom), & snap-in type. This cost effective series offers more
component options with better performance in curbing
common and differential mode noise. These filters are
equipped with IEC connector, fuse holder for one or two 5 x
20 mm fuses, 2 pole on/off switch and fully enclosed metal
housing.
These filters are also available for Medical equipment with
low leakage current and have been designed to bring various
medical equipments into compliance with EN55011 and FCC
Part 15J, Class B conducted emissions limits.
82
72
Use only with a 250V fuse
Employer uniquement avec
un fusible de 250V
28.5
4x R0.5
6.30 TYP.
-
40.0+ 0.2
RECOMMENDED PANEL CUTOUT
(MOUNT FROM FRONT)
R2.5 TYP.
2x 3.5
29.3
+0.5
60.8
+0.5
72.0
+0.1
29 6.3 TYP.
29.5
59.8
48.7
(3.5)
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
CASE C
(61.3)
(56.2)
TECHNICAL DATA
Rated Voltage: 125/250VAC
Rated Current: 1A, 2A, 3A, 4A, 6A, 10A
Power Line Frequency: 50/60Hz
Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.5mA, max
@ 250VAC 50Hz: 1.0mA, max
@ 125VAC 60Hz: 2
µ
A*, max
@ 250VAC 50Hz: 5
µ
A*, max
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
Temperature Range: -25C to +85C
* Medical application
65 59.5
Use only with a 250V fuse
Employer uniquement avec
un fusible de 250V
59.8
28
32
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
THICKNESS OF PANEL IS FROM
1.00mm to 1.6mm
48.7
(3.5)
R2.5 TYP.
29.3
+0.5
29 6.3 TYP.
61.4
+0.3
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com
81
dsp bootloader c5000
[size=4]Bootload problem. When I was learning 51 before, as long as the program was written and compiled, I could use the burner to burn the *.hex file directly into the microcontroller for operation....
灞波儿奔 Microcontroller MCU
Crystal oscillator problem
The network port circuit is as shown above. When testing it with an oscilloscope, I found that although there is a voltage value, there seems to be no sine wave. It is different from the waveform of t...
chenbingjy stm32/stm8
Design of PLC communication between CAN bus and computer
In modern industry, communication and networking between PLCs or between PLCs and computers are increasingly widely used. The networking function of PLCs is getting stronger and stronger. Taking Omron...
fish001 RF/Wirelessly
What are the introductory knowledge points for Web front-end?
First of all, we need to know what the front-end does and what software language it is developed in, so let's take a brief look at the front-end.  1. Code Editors/IDEs  As in 2019, Microsoft's VSCode ...
huaqingyuanjian Integrated technical exchanges
[TI's Big Live Broadcast] Let's get started! For 30 yuan, let's play with the new MSP430 that helps eliminate smog, vertical and horizontal sensing and measurement
TI's offline boutique hands-on training, which was originally limited to 30 people, has been moved online, and everyone can participate TI's new MSP430FR2355 is one of the protagonists of this trainin...
nmg Microcontroller MCU
HardFault location method and steps for smart microcontroller
Cortex-M0 processor core exception interrupt introduction The Cortex-M0 core is equipped with an exception response system that supports a variety of system exceptions and external interrupts. Among t...
火辣西米秀 Domestic Chip Exchange

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号