CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the
device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
NOTES:
2. Signals on NO, NC, COM, or IN exceeding V+ or V- are clamped by internal diodes. Limit forward diode current to maximum current ratings.
3.
θ
JA
is measured with the component mounted on a low effective thermal conductivity test board in free air. See Tech Brief TB379 for details.
Electrical Specifications -
±5V
Supply
Test Conditions: V
SUPPLY
=
±4.5V
to
±5.5V,
V
INH
= 3.5V, V
INL
= 1.5V (Note 4),
Unless Otherwise Specified
TEST CONDITIONS
TEMP
(°C)
Full
(NOTE 5)
MIN
V-
-
-
-
-
-1
-5
-1
-5
-2
-20
(V+) - 1.5
V-
-0.5
-
-
-
-
-
-
-
-
-
-
TYP
-
15
-
5
-
0.01
-
0.01
-
0.01
-
-
-
-
42
46
25
27
7
>90
58
13
13
30
(NOTE 5)
MAX
UNITS
V+
20
25
6
8
1
5
1
5
2
20
V+
(V+) - 3.5
0.5
70
85
45
50
20
-
-
-
-
-
V
Ω
Ω
Ω
Ω
nA
nA
nA
nA
nA
nA
V
V
µA
ns
ns
ns
ns
pC
dB
dB
pF
pF
pF
PARAMETER
ANALOG SWITCH CHARACTERISTICS
Analog Signal Range, V
ANALOG
ON Resistance, R
ON
R
ON
Flatness, R
FLAT(ON)
NO or NC OFF Leakage Current,
I
NO(OFF)
or I
NC(OFF)
COM OFF Leakage Current,
I
COM(OFF)
COM ON Leakage Current,
I
COM(ON)
V
S
=
±4.5V,
I
COM
= 1.0mA, V
COM
= 3V,
See Figure 4
V
S
=
±4.5V,
I
COM
= 1.0mA, V
COM
= -3V, 0V, 3V
V
S
=
±5.5V,
V
COM
=
±4.5V,
V
NO
or V
NC
= +4.5V, Note
6
V
S
=
±5.5V,
V
COM
=
±4.5V,
V
NO
or V
NC
= +4.5V, Note
6
V
S
=
±5.5V,
V
COM
= V
NO
or V
NC
=
±4.5V,
Note 6
25
Full
25
Full
25
Full
25
Full
25
Full
Full
Full
DIGITAL INPUT CHARACTERISTICS
Input Voltage High, V
INH
Input Voltage Low, V
INL
Input Current, I
INH
, I
INL
DYNAMIC CHARACTERISTICS
Turn-ON Time, t
ON
Turn-OFF Time, t
OFF
Charge Injection, Q
OFF Isolation
Power Supply Rejection Ratio
COM OFF Capacitance,
C
COM(OFF)
COM ON Capacitance, C
COM(ON)
V
NO
or V
NC
= 3V, R
L
= 300Ω, C
L
= 35pF,
V
IN
= 0 to V+, See Figure 1
V
NO
or V
NC
= 3V, R
L
= 300Ω, C
L
= 35pF,
V
IN
= 0 to V+, See Figure 1
C
L
= 1.0nF, V
G
= 0V, R
G
= 0Ω, See Figure 2
R
L
= 50Ω, C
L
= 15pF, f = 100kHz, See Figure 3
R
L
= 50Ω, C
L
= 5pF, f = 1MHz
f = 1MHz, V
NO
or V
NC
= V
COM
= 0V, See Figure 5
f = 1MHz, V
NO
or V
NC
= V
COM
= 0V, See Figure 5
25
Full
25
Full
25
25
25
25
25
25
V
S
=
±5.5V,
V
IN
= 0V or V+
Full
NO or NC OFF Capacitance, C
OFF
f = 1MHz, V
NO
or V
NC
= V
COM
= 0V, See Figure 5
3
ISL43112, ISL43113
Electrical Specifications -
±5V
Supply
Test Conditions: V
SUPPLY
=
±4.5V
to
±5.5V,
V
INH
= 3.5V, V
INL
= 1.5V (Note 4),
Unless Otherwise Specified
(Continued)
TEST CONDITIONS
TEMP
(°C)
Full
V
S
=
±5.5V,
V
IN
= 0V or V+, Switch On or Off
V
S
=
±5.5V,
V
IN
= 0V or V+, Switch On or Off
25
Full
Negative Supply Current, I-
25
Full
(NOTE 5)
MIN
±1.5
-
-
-25
-50
TYP
-
15
22
-15
-22
(NOTE 5)
MAX
UNITS
±6
25
50
-
-
V
µA
µA
µA
µA
PARAMETER
POWER SUPPLY CHARACTERISTICS
Power Supply Range
Positive Supply Current, I+
NOTES:
4. V
IN
= Input voltage to perform proper function.
5. The algebraic convention, whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
6. Leakage parameter is 100% tested at high temp, and guaranteed by correlation at 25°C.
The school opened a DSP course, so I started to enter the DSP field. The equipment provided by the school was the Beijing Baike Rongchuang experimental box RC-DSP-II+, which contained the C2000 series...
Pellicanusis an open source, RP2040-based INS/ GNSS module that you can program in MicroPython, C, or Rust. It allows you to add Vertical Reference Units (VRU), Attitude and Heading Reference Systems ...
I used ADS1220 to collect the sensor force value and did some filtering, but the force value still jittered a lot.I took the average of 32 points and used a de-jitter filter, but it didn't work.
The c...
Hello, I would like to ask some questions about the 24-bit SDADC of this chip. I am using e2 studio.
1. How can I get the time required to sample and convert a channel in the RA2A1 SDADC routine? I ha...
Abstract: Remote temperature sensors are now a common technique for monitoring the die temperature of high-performance microprocessors and image processors, and are used to manage system power and th...[Details]
FTTH testing is generally divided into several stages: installation and construction, activation and maintenance, and fault diagnosis.
During the installation and construction phase, the loss ...[Details]
1 Hardware composition
The detection system is mainly composed of two parts: signal interface and virtual instrument (Figure 1). The signal to be tested is led out from the interface on the contro...[Details]
Xiali is a banner of Tianjin's automobile industry. Although Tianjin's automobile production capacity and output value are only in the middle of the country, new energy vehicles are developing rapi...[Details]
With the development of an absolute linear travel measuring device, the product range of Newall Ltd in Leicester has been further improved. The British measurement technology specialist is now able to...[Details]
Recently, Tang Yongbing (corresponding author), a researcher at the Functional Thin Film Materials Research Center of the Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, and h...[Details]
At the 2024 Chengdu International Auto Show, the most eye-catching thing is that the bosses of major companies promoted their own companies online and offline to attract traffic.
This ye...[Details]
The design uses Motorola's integrated chip MPXY8020A for TPMS as the main device of the tire pressure detection unit, which further reduces the size of the system and reduces the power consumption ...[Details]
According to Jiwei.com, on August 17, Ningbo Bird Co., Ltd. (hereinafter referred to as Bird) issued a clarification announcement stating that there have been online rumors recently that Honor Mobile...[Details]
In the post-epidemic era, the epidemic situation is recurring, coupled with the aging population and the continuous improvement of residents' health awareness, the demand for medical services con...[Details]
Heart rate (HR) and blood oxygen saturation (SpO2) are quickly moving from the “nice to have” stage to the “hope to have” stage in the list of features for health and fitness wearables. However, th...[Details]
1. Advantages of sewage flow meter: (1) The measuring channel of the sewage flow meter is a smooth straight tube without flow-blocking detection parts. Because it is not easy to be blocked, it is sui...[Details]
1. Issues to consider when wiring
1. Number of information points
Generally, since the master bedroom usually has two owners, it is recommended to install two information points so that both...[Details]
1 Introduction
Milk is becoming more and more common in people's daily life and diet. Real-time, fast and accurate detection of milk ingredients is of great significance to improving milk ...[Details]