5 x 15mm Axial-Leaded, Time-Delay, Glass Tube Fuses
C515 Series
Dimensions
- mm
Drawing Not to Scale
Description
• Axial-leaded, time-delay
• 5 x 15mm physical size
• Nickel-plated brass endcap construction
• Leads are tin coated
• Optional sleeve is flexible flouropolymer
(UL Flammability rating VW-1).
• UL Listed product meets standard UL 248-14
Agency Information
• UL Listed Card: C515 125mA-250mA and 375mA-3A
(Guide JDYX, File E19180)
• UL Recognized Card: C515 350mA, and 3.5A-7A
(Guide JDYX2, File E19180)
• CSA Certification Card: C515 125mA-250mA and
375mA-3A (Class 1422-01, 53787
Ordering
Specify product code
• Insert packaging code prefix before part number.
E.g., BK (or TR2)/C515-2-R
• With TR2 packaging code, lead wire length is 20.3mm
Specify option code, if desired
• For insulation sleeve, insert “S” after part series.
E.g., BK/C515S-2-R
Voltage
Rating
Vac
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
125
125
125
125
125
Electrical Characteristics
Amp Rating
Opening Time
135%
60 minutes max.
125mA - 250mA
3 seconds min.
200%
120 seconds max.
100%
4 hours min.
470mA
30 minutes max.
350mA
600mA
90 seconds max.
2A
2 seconds max.
6A
500 milliseconds max.
135%
60 minutes max.
375mA - 7A
3 seconds min.
200%
120 seconds max.
Rated Current
Specifications
Product Code
C515-125-R
C515-250-R
C515-350-R
C515-375-R
C515-500-R
C515-600-R
C515-750-R
C515-800-R
C515-1-R
C515-1.25-R
C515-1.5-R
C515-1.6-R
C515-2-R
C515-2.25-R
C515-2.5-R
C515-3-R
C515-3.5-R
C515-4-R
C515-5-R
C515-6-R
C515-7-R
Interrupting
Rating (amps)
600Vac
250Vac
125Vac
-
35
10000
-
35
10000
25
35
10000
-
35
10000
-
35
10000
-
35
10000
-
35
10000
-
35
10000
-
35
10000
-
100
10000
-
100
10000
-
100
10000
-
100
10000
-
100
10000
-
100
10000
-
100
10000
-
-
400
-
-
400
-
-
400
-
-
400
-
-
400
Typical DC Cold
Resistance*
Ω
(Ω)
4.72
1.32
1.04
0.81
0.54
0.38
0.26
0.23
0.14
0.13
0.100
0.090
0.059
0.057
0.046
0.035
0.028
0.023
0.019
0.014
0.013
Typical
Melting I
2
t**
0.101
0.467
1.169
1.531
2.280
6.982
9.162
10.544
14.289
22.961
31.989
35.156
60.256
97.724
78.163
80.426
149.279
233.346
354.813
471.360
710.500
Max
Voltage
Drop (mV)***
770
430
530
470
440
350
310
260
230
220
240
200
170
180
190
150
130
130
150
125
100
*DC Cold Resistance (Measured at <10% of rated current)
**Typical Melting I
2
t (A
2
Sec) (Minimum I
2
t at 10 times rated current)
***Typical Voltage Drop (Voltage drop was measured at 25°C ambient temperature at rated current)
1009
BU-SB09716
Page 1 of 2
Data Sheet 2006
Time-Current Curves
600mA
750mA
800mA
1A
250mA
375mA
125mA
350mA
500mA
2A
2.25A
2.5A
1.25A
1.5A
1.6A
3A
3.5A
4A
10000
1000
100
Pre-arcing time (s)
10
1
0.1
0.01
0.1
1
Multiples of Rated Current
10
100
Packaging Code
Packaging Code Prefix
BK
TR2
Description
100 fuses packed into a cardboard carton
1500 fuses packed into tape on a reel (20.3mm lead wire length)
Option Code
Option Code
S
Description
Insulation Sleeve
The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is
intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change
design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained
in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
Life Support Policy: Cooper Bussmann does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support
systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in
significant injury to the user.
© 2010 Cooper Bussmann
St. Louis, MO 63178
www.cooperbussmann.com
0310
BU-SB09716
Page 2 of 2
6A
7A
5A
Data Sheet 2006