10-90A
mp
• 120/240 V
ac
- AC OUTPUT
•
Zero Voltage and Random
Turn-On Switching
•
Panel Mount
•
600V Transient Capability
•
Internal Snubber
•
110 & 125A Models
Available
•
Integrated Overvoltage
Protection by Automatic
Self Turn-On (Suffix P)
MODEL NUMBERS
AC CONTROL
D C CONTROL
A1210
D1210
A1225
D1225
A1240
D1240
S
eries
1
Featuring state-of-the-art Surface
Mount Technology, these SPST-NO
relays deliver proven reliability in the
most demanding applications. Output
consists of an SCR AC switch and is
available in zero-cross, random turn-
on (phase controllable) and normally
closed (Form B) versions with either
AC or DC input (coil) control.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
A2425
D2425
A2450
D2450
A2475
D2475
A2490
D2490
A2410
D2410
OUTPUT SPECIFICATIONS
➀
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current
24-140
10
40
400
120
1.6
1.48
60
8
500
24-140
25
40
400
250
1.6
1.02
260
8
500
24-140
40
40
400
625
1.6
0.63
1620
8
500
24-280
10
40
600
120
1.6
1.48
60
10
500
24-280
25
40
600
250
1.6
1.02
260
10
500
24-280
50
40
600
625
1.6
0.63
1620
10
500
24-280
75
40
600
1000
1.6
0.31
4150
10
500
24-280
90
40
600
1200
1.6
0.28
6000
10
500
➂
[Arms]
Min. Load Current, [mArms]
Transient Overvoltage [Vpk]
Max. Surge Current, (16.6ms) [Apk]
Max. On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (R
θJC
[˚C/W]
)
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
Max. Turn-On Time
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
➁
➃
0.5
1/2 Cycle (DC Control), 10.0 msec (AC Control)
1/2 Cycle (DC Control), 40.0 msec(AC Control)
0.5
0.5
0.5
0.5
0.5
0.5
0.5
INPUT SPECIFICATIONS
➀
Control Voltage Range
Max. Reverse Voltage
Max. Turn-On Voltage
Min. Turn-Off Voltage
Nominal Input Impedance
Typical Input Current
DC CONTROL
3-32 Vdc
-32 Vdc
3.0 Vdc
1.0 Vdc
1500 Ohms
AC CONTROL
90-280 Vrms (60Hz)
---
90 Vrms
10 Vrms
60K Ohms
2mA @ 120 Vrms, 4mA @ 240 Vrms
AC CONTROL
(E SUFFIX)
18-36 Vrms
---
18 Vrms
4.0 Vrms
9.0K Ohms
3mA @ 24 Vrms
3.4mA @ 5 Vdc, 20mA @ 28Vdc
GENERAL NOTES
© 2003 CRYDOM CORP, Specifications subject to change without notice.
➀
All parameters at 25˚ C unless otherwise specified.
➁
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂
Heat sinking required, for derating curves see page 3.
➃
Turn-on time for random turn-on versions is 0.02 msec (DC Control Models).
For recommended applications and more information contact:
USA: Sales Support
(877) 502-5500
Tech Support
(877) 702-7700
FAX
(619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email:
sales@crydom.com
WEB SITE:
http://www.crydom.com
UK:
+44 (0)1202 365070 •
FAX
+44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE,
Email:
intsales@crydom.com.
GERMANY:
+49 (0)180 3000 506
FastFax Document No. 151
SERIES1
Rev. 102104
PAGE 1 OF 3
10-90A
mp
• 120/240 V
ac
- AC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
Insulation Resistance (Min.) @ 500 Vdc
Max. Capacitance Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
MECHANICAL SPECIFICATIONS
Weight: (typical)
Encapsulation:
Terminals:
AVAILABLE OPTIONS
-B
Normally Closed (Form B)
Example:
D2450-B, A2450-B
E
F
G
24 Vac Input (18-36 Vac)
Example:
A2450E
Faston Terminals (Up to 50A Models)
Example:
D1225F
Input Status LED.
Agencies Approval Pending
Example:
D2450G
Note:
Control Voltage Range 4.5-32Vdc
for DC Control Models.
Internal Overvoltage Protection.
Relay Will Self Trigger Between
450-600 Vpk. Not Suitable For Capacitive Loads.
Not Available with -B Option
Agencies Approval Pending.
Example:
D2425P
400 Hz Operation
10-50 Amp Models Only
Zero Cross Switching Only
Example:
4D2450
Random Turn-On (AC & DC Control)
Phase Controllable (DC Control)
Example:
D2450-10
1
1.87
(47.5)
OUTPUT
S
eries
1
4000 Vrms
10
9
Ohm
8 pF
-40 to 80˚C
-40 to 125˚C
3.0 oz. (86.5g)
Thermally Conductive Epoxy
Screws and Saddle Clamps Furnished, Unmounted
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
8-32 TERMINAL
(2 PLACES )
2
--
4
INPUT
+
3
2.30
(58.4)
1.70
(43.2)
BASE PLATE
.125 (3.2)
1.00
(25.4)
1.80
(45.7)
6-32 TERMINAL
(2 PLACES)
.78
(19.8)
.90
(22.9)
P
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
1.10
(27.9)
.45
(11.4)
FASTON TERMINAL
.250 X .032 (2 PLCS.)
.87 REF.
(22.2)
4D
Screw Torque Requirements:
6-32 Screws - 10 in. lbs.,
8-32 and 10-32 Screws - 20in. lbs.
(Screws dry without grease.)
Fastons:
Single pair (up to 25A)
Double pair* (up to 50A).
*Caution: User must connect to both pairs
1.87
(47.5)
1
OUTPUT
2
2.30
(58.4)
1.70
(43.2)
4
--
INPUT
+
3
-10
BASE PLATE
.125 (3.2)
1.00
(25.4)
1.80
(45.7)
FASTON
TERMINAL
.187 X .032
(2 PLCS.)
.78
(19.8)
.90
(22.9)
H
Heat Transfer Pad (Attached)
Example:
D2450H
Ordering System:
Combination of the
suffixes should be made in the following order:
EFPG-10.
Example:
A2450EFPG-10
Crydom Heat Sinks
offer excellent
thermal management and are per
-
fectly matched to the load current rat
-
ings of Crydom panel mount relays.
Request Crydom’s Heat Sink specifica
-
tion sheet for all the details.
All dimensions are in inches (millimeters)
APPROVALS
UL
E116949
CSA LR81689
VDE 10143 UG (Not Applicable: -B and 4D)
FastFax Document No.151
SERIES1
Rev. 102104
PAGE 2 OF 3
© 2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support
(877) 502-5500
Tech Support
(877) 702-7700
FAX
(619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email:
sales@crydom.com
WEB SITE:
http://www.crydom.com
UK:
+44 (0)1202 365070 •
FAX
+44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE,
Email:
intsales@crydom.com.
GERMANY:
+49 (0)180 3000 506
10-90A
mp
• 120/240 V
ac
- AC OUTPUT
S
eries
1
CURRENT DERATING CURVES
10A
12
7˚C/W
9˚C/W
3˚C/W
25A
30
1˚C/W
95
Base Plate Temp [˚C]
Base Plate Temp [˚C]
5˚C/W
Base Plate Temp [˚C]
110
25
Power Dissipation
3˚C/W
2˚C/W
100
Power Dissipation
8
NO HEATSINK
20
15
10
NO HEATSINK
115
110
4
120
5
0
2
4
6
8
10
20
40
60
80
Load Current [Arms]
Max Ambient Temp. [˚C]
120
5
10
15
20
25
20
40
60
80
0
Load Current [Arms]
Max Ambient Temp. [˚C]
50A
60
1˚C/W
1.5˚C/W
.5˚C/W
75A
120
90
Base Plate Temp [˚C]
Base Plate Temp [˚C]
90A
120
.5˚C/W
.2˚C/W
.4˚C/W
90
95
Power Dissipation
.5˚C/W
.3˚C/W
Power Dissipation
40
2˚C/W
100
80
1˚C/W
100
Power Dissipation
80
1˚C/W
100
20
NO HEATSINK
110
110
40
120
0
110
40
120
0
20
40
60
80
0
20
40
60
80
120
80
15
30
45
60
75
20
40
60
80
0
10
20
30
40
50
20
40
60
Load Current [Arms]
Max Ambient Temp. [˚C]
Load Current [Arms]
Max Ambient Temp. [˚C]
Load Current [Arms]
Max Ambient Temp. [˚C]
© 2003 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No.151
SERIES1
Rev. 102104
PAGE 3 OF 3
For recommended applications and more information contact:
USA: Sales Support
(877) 502-5500
Tech Support
(877) 702-7700
FAX
(619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email:
sales@crydom.com
WEB SITE:
http://www.crydom.com
UK:
+44 (0)1202 365070 •
FAX
+44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE,
Email:
intsales@crydom.com.
GERMANY:
+49 (0)180 3000 506