COMPACT SIZE SIDE
LIMIT SWITCHES
ML (AZ7)
Limit Switches
• Long life
More than 10
7
mechanical operations.
• Great mechanical strength while being compact and lightweight
Strong plastic outer cover cap with excellent mechanical
characteristics.
M4 bolt can be used for mounting.
• The overtravel (O.T.) is large with great shock absorption
• Dust-proof and oil resistant
Flushed with the diaphragm and the compressed rubber ring
Conforms to UL/CSA TÜV standards.
PRODUCT TYPE
1. Standard type
Actuator
Short push plunger
Push plunger
Hinge lever
Roller lever
One-way roller lever
Hinge short lever
Short roller lever
One-way short roller lever
Panel mount push plunger
Panel mount roller plunger
Panel mount cross roller plunger
Flexible rod
Part No.
AZ7100
AZ7110
AZ7120
AZ7121
AZ7124
AZ7140
AZ7141
AZ7144
AZ7310
AZ7311
AZ7312
AZ7166
Note 1. Cadmium free contact types are available on a custom-made basis.
Please add an “F” to the end of the part number when ordering.
FOREIGN STANDARDS
Standards
UL
CSA
TÜV
Applicable product
File No.
: E-122222
Ratings
: 10A 250V AC
Product type : Standard type only
File No.
: LR55880
Ratings
: 10A 250V AC
Product type : Standard type only
File No.
: J9551204
Ratings
: AC-15 2A/250V~
Product type : Standard type only
Part No.
Order by standard part No.
SPECIFICATIONS
1. Rating
Rated control voltage
125V AC
250V AC
115V DC
Load
Resistive load (cosφ]1)
10A
10A
0.4A
Inductive load (cosφ]0.4)
6A
4A
0.05A
Motor or lamp load
N.C. contact
N.O. contact
3A
1.5A
1.5A
1A
–
–
22
10/2010
ML (AZ7)
2.Characteristics
Contact arrangement
Initial contact resistance, max.
Initial insulation resistance (At 500V DC)
Initial breakdown voltage
Shock resistance
Vibration resistance
Mechanical
Electrical
Ambient temperature/Ambient humidity
Max. operating speed
Expected life
(Min. operation)
* The resistance of a copper wire is not included.
In the free position
In the full operating position
1 Form C
15mΩ* (By voltage drop 6 to 8V DC at rated current)
Min. 100 mΩ
1,500 Vrms for 1 min between non-consecutive terminals
2,000 Vrms for 1 min between dead metal parts and each terminal
2,000 Vrms for 1 min between ground and each terminal
Max. 98m/s
2
{10G}
Max. 294m/s
2
{30G}
55 Hz, double amplitude of 1.5 mm
10
7
(at 50 cpm)
2 x 10
5
(at 20 cpm)
–20 to +60°C
–4 to +140°F/Max.
95% R.H. (at 20°C
68°F)
120 cpm
3.EN60947-5-1 performance
Item
Rated insulation voltage (Ui)
Rated impulse withstand voltage (Uimp)
Switching over voltage
Rated enclosed thermal current (Ithe)
Conditional short-circuit current
Short-circuit protection device
Protective construction
Pollution degree
Rating
250VAC
2.5kV
2.5kV
10A
100A
10A fuse
IP64 (switch)
3
DATA
1. Life curve
10
8
Operations (
210
4
)
10
7
10
6
1
2
5V
AC
cos
φ
1
4. Operating characteristics
Characteristics
Actuator
Short push plunger
Push plunger
Hinge lever
Roller lever
One-way roller lever
Hinge short lever
Short roller lever
One-way short roller lever
Panel mount push plunger
Panel mount roller plunger
Panel mount cross roller plunger
Flexible rod
O.F. (N{gf})
max.
5.88 {600}
5.88 {600}
1.47 {150}
1.77 {180}
1.96 {200}
2.16 {200}
2.35 {240}
2.75 {280}
5.88 {600}
5.88 {600}
5.88 {600}
1.18 {120}
R.F. (N{gf})
min.
0.98 {100}
0.98 {100}
0.39 {40}
0.49 {50}
0.59 {60}
0.59 {60}
0.78 {80}
0.98 {100}
0.98 {100}
0.98 {100}
0.98 {100}
–
Movement
Pretravel
Overtravel
Differential
(P.T.), max.
(O.T.), min.
(M.D.), max.
mm
inch
mm
inch
mm
inch
2.0
.079
0.8
.031
0.8
.031
2.0
.079
0.8
.031
5.0
.197
13.5
.531
3.2
.126
4.0
.157
11.0
.433
2.4
.094
3.0
.118
11.0
.433
2.4
.094
3.0
.118
8.5
.335
2.0
.079
2.5
.098
6.5
.256
1.5
.059
2.0
.079
6.5
.256
1.5
.059
2.0
.079
2.0
.079
0.8
.031
6.0
.236
2.0
.079
0.8
.031
6.0
.236
2.0
.079
0.8
.031
6.0
.236
25
.984
–
11
.433
Operating Position
(O.P.) mm
inch
30±0.8
1.181±.031
44±1.2
1.732±.047
25±2.0
.984±.079
40±1.9
1.575±.75
50±2.0
1.969±.079
25±1.3
.984±.051
40±1.6
1.575±.063
50±1.6
1.969±.063
21.8±0.8
.858±.031
33.3±1.2
1.311±.047
33.3±1.2
1.311±.047
36
1.417
(T.T.)
10
5
5
10
Load current (A)
WIRING DIAGRAM
Circuit
ML
COM
N.C.
N.O.
Terminal
Note) For the operating characteristics, refer to the TECHNICAL INFORMATION.
5. Protective characteristics
Protective construction
IEC
IP60
IP64
Screw terminal type
–
Epoxy-sealed terminal type
COM
N.O.
N.C.
CAUTIONS
1. When the switch is to be used in plac-
es where oil or is abundant, bore a drain
hole in the bottom of the terminal cover.
2. Avoid places where highly acid or alkaline
fluids are used or high temperatures prevail.
3.Wiring
(1) Remove the terminal cover with a
v
driver.
(2) Insert the lead wire through the
knock-out of the terminal cover.
(3) Connect the lead wire to the terminal.
When connecting the terminals with the
fasten lug, those with the insulation
sleeve are recommended.
(4) The terminal cover can be mounted in
both directions.
N.C.
COM
In this case, fasten the terminal cover in
the opposite direction.
•Forepoxy-sealedterminaltypes,there
are two types by the cord outlet direction;
N.C. side and COM side.
4. Flexible rod type
(1) Put the detective object to the tip of
plastic part.
(2) Avoid pushing the tip of actuating
spring in the direction of axis. In the plac-
es of oil or water splashes and much
dust area, use the limit switch with keep-
ing the actuating spring in the vertical
direction.
Standard
10/2010
23