Designed in accordance with the requirements of IEC 62314
IEC 61000-4-2 : Electrostatic Discharge – Level 3
IEC 61000-4-4 : Electrically Fast Transients – Level 3
IEC 61000-4-5 : Electrical Surges – Level 3
IEC 600068-2-6: Vibration 0.33mm and 0.75mm Amplitude over 10-55 Hz
IEC 600068-2-27: Shock Resistance 15g/11ms
E116949 (25, 50, 75 and 90A)
E116950 (125A)
LR81689
10143 UG
ACCESORIES
Protective Cover & Hardware Kits
Part number: KS101
Clear plastic cover compatible with all new
S1 designs. Safety covers provide added
protection from electric shock when
installing or checking equipment.
Recommended Accessories
Protective Cover
Cover
KS101
Hardware
Kit
HK1
HK4
Heat Sink
Part No.
HS501DR
HS301 / HS301DR
HS251
HS202 / HS202DR
HS201 / HS201DR
HS172
HS151 / HS151DR
HS122 / HS122DR
HS103 / HS103DR
HS101
HS073
HS072
HS053
HS033
HS023
Thermal Resistance
Lug Terminal Thermal Pad
[ºC/W]
5.0
3.0
2.5
2.0
2.0
1.7
1.5
1.2
1.0
1.0
0.7
0.7
0.5
0.36
0.25
TRM1
TRM6
HSP-1
HSP-2
Hardware Kit
Part number: HK4
Bag with 2 square brass accessories and 2
screw 8-32 x 5/8 for output. Used to mount
TMR1 lug terminals.
GENERAL NOTES
(1)
Single pair (up to 25A) Double pair* (50A model only).
*Caution:
User must connect to both pairs
(2)
Option “K” is designed and tested for use with printed circuit boards or ring/fork terminals having a thickness between 0.031 and 0.093 inches (0.79 to 2.36 mm), and loads rated up to 50 Amps.
For higher load currents, the “K” standoff temperature must not exceed 105°C. For additional application assistance please contact Crydom Technical Support.
(3)
Output
will self trigger between 900-1200Vpk, Min. power factor 0.7 or higher, not suitable for capacitive loads.
(4)
Instantaneous turn-on version is not recomended for capacitive loads. Use zero turn-on only.
(5)
All parameters at 25°C unless otherwise specified.
(6)
Heat sinking required, see derating curves.
(7)
Increase minimum voltage by 1V for operations from -20 to -40°C.
(8)
Turn-on time for Instantaneous turn-on versions is 0.02 msec.
(9)
All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report).
(10)
Load can be wired to either SSR output terminal 1 or 2.
(11)
Elective Input Status LED, “G” option.
(12)
Elective Overvoltage Protection, “P” option.
(13)
Mechanical dimensions vary from G3 models.
For additional information or specific questions, contact Crydom Technical Support.
First of all, I would like to thank Eeworld and Anxin for providing the GW1N series development boards. Now, due to the impact of the epidemic and other factors, the shortage of overseas chips and the...
After getting used to single-ended signals, it is still a bit scary to use differential signals. Therefore, some device manufacturers, although the input interface is differential, will indicate the s...
[size=4][color=#000000][backcolor=white]The purpose of restrict is to restrict a pointer's access to a block of memory. To put it more concretely, if a memory area is accessed through a restricted poi...