(1/6)
DC to DC Converters
Distributed Power Supplies for Systems, Insulation Type
Half Brick Type iHA/iHD Series
Power supply systems for infrastructure devices used in communi-
cation networks primarily use brick-type DC to DC converters.
As the voltage used for LSIs continues to drop, power supplies are
expected to provide lower output, higher efficiencies, and lower
noise levels. Moreover, the high-power is needed in the mid output
voltage such as RF lamps.
To meet these demands, we have developed half brick types with
low output voltage.
FEATURES
• Wide input voltage range (DC.36 to 75V)
• There are 19 models in the lineup of products with low to
medium output voltages.
• High efficiency: 92%(5V and 28V output)
• Heat sink is not required.
• Remote ON-OFF function
• Output voltage external variable function
• Remote sensing function
• Various protective functions
• Parallel operations are available only for iHD type
PRODUCT IDENTIFICATION
iHA
(1)
48 060A
(2)
(3)
012V
(4)
-
(5)
PART NUMBERS AND RATINGS
Output voltage(V)
Current(A)
Part No.
Low output voltage type
1.2
60
iHA48060A012V
1.5
60
iHA48060A015V
1.8
60
iHA48060A018V
2.5
60
iHA48060A025V
3.3
40
iHA48040A033V
3.3
60
iHA48060A033V
5
40
iHA48040A050V
Low output voltage type(supports parallel operations)
1.2
60
iHD48060A012V
1.5
60
iHD48060A015V
1.8
60
iHD48060A018V
2.5
60
iHD48060A025V
3.3
60
iHD48060A033V
5
40
iHD48040A050V
Mid output voltage type
12
25
iHA48025A120V
24
12.5
iHA48013A240V
28
11
iHA48011A280V
28
8
iHA24008A280V(24V input)
Mid output voltage type(supports parallel operations)
12
25
iHD48025A120V
24
12.5
iHD48013A240V
28
11
iHD48011A280V
28
8
iHD24008A280V(24V input)
(1) Type name
iHA/iHD: Half brick type
(2) Rated input voltage
(3) Output current
(4) Output voltage
(5) Option code
001: Standard(Negative on/off logic, Pin length: 3.68mm,
Shutdown type OVP)
000: Positive on/off logic, Pin length: 3.68mm,
Shutdown type OVP
002: Positive on/off logic, Pin length: 3.68mm,
Automatic recovery type OVP
003: Negative on/off logic, Pin length: 3.68mm,
Automatic recovery type OVP
004: Positive on/off logic, Pin length: 2.79mm,
Shutdown type OVP
005: Negative on/off logic, Pin length: 2.79mm,
Shutdown type OVP
006: Positive on/off logic, Pin length: 2.79mm,
Automatic recovery type OVP
007: Negative on/off logic, Pin length: 2.79mm,
Automatic recovery type OVP
• All specifications are subject to change without notice.
002-02 / 20040525 / ea33_br_ihad.fm
(2/6)
SPECIFICATIONS AND STANDARDS
General use
Supports parallel operations
Rated output voltage and current
∗1
Maximum output power
W
Input conditions
Input voltage Edc
V
Input current
A
Inrush transient
∗2
A
2
S
Efficiency
%
Output characteristics
Output voltage Edc
V
Voltage adjustment range
%
Maximum output current
A
Minimum output current
A
Output voltage initial setting
%
Overvoltage protection
V
Overcurrent protection
A
Line regulation
mV
Load regulation
mV
Voltage
Temperature
stability
mV
regulation
Dynamic response
∗3
mV
Ripple noise Ep-p
mV
Start up time
ms
Auxiliary functions
Overvoltage protection
Overcurrent protection
Alarm output
Over-temperature protection
Remote ON-OFF
Remote sensing
Parallel operation
Output voltage adjustment
Master slave operation
Standards
Safety standards
Constructions
External dimensions
mm
Weight
g
Mounting method
Oscillating method
Oscillating frequency
kHz
Part No.
∗1
∗2
iHA48060A012V
iHD48060A012V
1.2V • 60A
72
iHA48060A015V
iHD48060A015V
1.5V • 60A
90
iHA48060A018V
iHD48060A018V
1.8V • 60A
108
iHA48060A025V
iHD48060A025V
2.5V • 60A
150
iHA48040A033V
3.3V • 40A
132
iHA48060A033V
iHD48060A033V
3.3V • 60A
200
iHA48040A050V
iHD48040A050V
5.0V • 40A
200
36 to 75[Continuation]/100[Transient 100ms]
2.6max.
3.2max.
3.7max.
0.02max.
0.02max.
0.02max.
83typ.
86typ.
86.5typ.
1.2
–46 to +10
60
0
±1.7max.
1.65typ.
76typ.
2max.(1typ.)
6max.(4typ.)
15max.
(10typ.)
±35typ.
40typ.
32typ.
1.5
–46 to +10
60
0
±1.7max.
2.0typ.
72typ.
4max.(2typ.)
6max.(4typ.)
30max.
(10typ.)
±100typ.
50typ.
70typ.
1.8
–46 to +10
60
0
±1.7max.
2.2typ.
71typ.
4max.(2typ.)
6max.(4typ.)
30max.
(10typ.)
±100typ.
50typ.
70typ.
5.2max.
0.02max.
89typ.
2.5
–46 to +10
60
0
±1.6max.
3.2typ.
68typ.
5max.(2typ.)
8max.(4typ.)
30max.
(10typ.)
±100typ.
50typ.
70typ.
4.5max.
0.02max.
90typ.
3.3
–46 to +10
40
0
±1.6max.
4.4typ.
46typ.
6max.(2typ.)
10max.(6typ.)
30max.
(10typ.)
±110typ.
60typ.
70typ.
6.2max.
0.02max.
90typ.
3.3
–46 to +10
60
0
±1.6max.
4.4typ.
66typ.
6max.(2typ.)
10max.(6typ.)
30max.
(10typ.)
±110typ.
50typ.
70typ.
6.8max.
0.02max.
92typ.
5
–46 to +10
40
0
±1.6max.
6.0typ.
46typ.
8max.(2typ.)
10max.(4typ.)
40max.
(15typ.)
±150typ.
150typ.
70typ.
Yes(Shut-down type: Models capable of automatic output voltage recovery are available as an option.)
Yes(Automatic recovery)
No
Yes(Automatic recovery)
Yes
Yes
Impossible
Yes
No
UL60950 and VDE0805 approved. EN60950 approved.
12.7×57.9×61.0[H×W×L]
25typ.
Mounted from the terminal side (soldered).
Fixed frequency
300typ.[1.2V and 1.5V output: 240kHz]
Verify the rated current (maximum output current) because this involves derating.
Applies only to the primary surge. The power supply does not have an input fuse, so make sure to install an external fuse when using this product.
∗3
Load step from 50 to 75% of Io max.
• All specifications are subject to change without notice.
002-02 / 20040525 / ea33_br_ihad.fm
(3/6)
SPECIFICATIONS AND STANDARDS
General use
Supports parallel operations
Rated output voltage and current
∗1
Maximum output power
W
Input conditions
Input voltage Edc
V
Input current
A
Inrush transient
∗2
A
2
S
Efficiency
%
Output characteristics
Output voltage Edc
V
Voltage adjustment range
%
Maximum output current
A
Minimum output current
A
Output voltage initial setting
%
Overvoltage protection
V
Overcurrent protection
A
Line regulation
mV
Load regulation
mV
Voltage
Temperature
stability
mV
regulation
Dynamic response
∗3
mV
Ripple noise Ep-p
mV
Start up time
ms
Auxiliary functions
Overvoltage protection
Overcurrent protection
Alarm output
Over-temperature protection
Remote ON-OFF
Remote sensing
Parallel operation
Output voltage adjustment
Master slave operation
Standards
Safety standards
Constructions
External dimensions
mm
Weight
g
Mounting method
Oscillating method
Oscillating frequency
kHz
Part No.
∗1
∗2
iHA48025A120V
iHD48025A120V
12V • 25A
300
iHA48013A240V
iHD48013A240V
24V • 12.5A
300
iHA48011A280V
iHD48011A280V
28V • 11A
308
iHA24008A280V
iHD24008A280V
28V • 8A
225
36 to 75[Continuation]/100[Transient 100ms]
10.2max.
10.2max.
0.02max.
0.02max.
92typ.
91typ.
12
–46 to +10
25
0
±1.7max.
14typ.
31typ.
15max.(5typ.)
25max.(10typ.)
100max.(40typ.)
±250typ.
150typ.
70typ.
24
–46 to +10
12.5
0
±1.7max.
29typ.
15.2typ.
25max.(10typ.)
50max.(10typ.)
200max.(75typ.)
±500typ.
350typ.
40typ.
10.2max.
0.02max.
92typ.
28
–46 to +10
11
0
±1.8max.
33.5typ.
13.6typ.
30max.(10typ.)
50max.(10typ.)
200max.(85typ.)
±500typ.
350typ.
70typ.
15max.
0.02max.
92typ.
28
–46 to +10
8
0.8
±1.8max.
33.0typ.
10.1typ.
30max.(10typ.)
50max.(10typ.)
200max.(85typ.)
±500typ.
250typ.
60typ.
Yes(Shut-down type: Models capable of automatic output voltage recovery are available as an option.)
Yes(Automatic recovery)
No
Yes(Automatic recovery)
Yes
Yes
Impossible
Yes
No
UL60950 and VDE0805 approved. EN60950 approved.
12.7×57.9×61.0[H×W×L]
25typ.
Mounted from the terminal side (soldered).
Fixed frequency
300typ.[1.2V and 1.5V output: 240kHz]
Verify the rated current (maximum output current) because this involves derating.
Applies only to the primary surge. The power supply does not have an input fuse, so make sure to install an external fuse when using this product.
∗3
Load step from 50 to 75% of Io max. with 200µF external capacitor.
• All specifications are subject to change without notice.
002-02 / 20040525 / ea33_br_ihad.fm
(4/6)
SHAPES AND DIMENSIONS
Bottom view
57.9
4.8
48.26
50.80
61.0
3.68±0.50
12.7
5.1
M3×0.5
Threaded inserts
4 places
ø1.02
7 pins
ø2.03
2 pins
TERMINAL DESIGNATIONS AND FUNCTIONS
Top view
57.9
5.1
4.8
48.26
7.62
10.16
25.40
10.16
17.78
1
9
35.56
43.69
7
3
6
4
5
Dimensions in mm
1
2
3
4
5
6
7
8
9
+Vin
On/Off
Case
–Vin
–Vout
–Sense
Trim
+Sense
+Vout
DC input terminal (+)
The output can be turned on/off externally.
Do not connect anything.
DC input terminal (–)
DC output terminal (–)
Remote sensing terminal (–)
The output voltage can be varied by an external resistor.
Remote sensing terminal (+)
DC output terminal (+)
• All specifications are subject to change without notice.
002-02 / 20040525 / ea33_br_ihad.fm
35.56
2
8
61.0
25.40
(5/6)
OUTPUT POWER-AMBIENT TEMPERATURE (DERATING)
MAXIMUM OUTPUT CURRENT vs. AMBIENT TEMPERATURE(Ta)
iHA48060A012V/iHD48060A012V
Wind direction: From output side to input side, Vin=48V
60
iHA48060A015V/iHD48060A015V
Wind direction: From output side to input side, Vin=48V
60
Output current (A)
Output current (A)
NC(0.3m/s, 60LFM)
1.0m/s(200LFM)
2.0m/s(400LFM)
30
40
50
60
70
Ambient temperature (˚C)
80
90
50
50
40
40
NC
1.0m/s(200LFM)
2.0m/s(400LFM)
30
40
50
60
70
Ambient temperature (˚C)
30
20
30
20
80
90
iHA48060A018V/iHD48060A018V
Wind direction: From output side to input side, Vin=48V
60
iHA48060A025V/iHD48060A025V
Wind direction: From output side to input side, Vin=48V
60
50
Output current (A)
50
Output current (A)
NC
1.0m/s(200LFM)
2.0m/s(400LFM)
30
40
50
60
70
Ambient temperature (˚C)
40
40
30
NC
1.0m/s(200LFM)
2.0m/s(400LFM)
30
40
50
60
70
Ambient temperature (˚C)
80
90
30
20
80
90
20
20
iHA48060A033V/iHD48060A033V
Wind direction: From output side to input side, Vin=48V
60
iHA48040A050V/iHD48040A050V
Wind direction: From output side to input side, Vin=48V
40
50
Output current (A)
Output current (A)
30
40
20
NC(0.3m/s, 60LFM)
1.0m/s(200LFM)
2.0m/s(400LFM)
30
40
50
60
70
Ambient temperature (˚C)
80
90
30
20
20
30
40
50 60 70 80 90 100 110 120
Ambient temperature (˚C)
2.0m/s(400LFM)
3.0m/s(600LFM)
IMS LIMIT 1.3m/s(250LFM)
IMS LIMIT 1.3m/s(250LFM)
10
20
NC
0.5m/s(100LFM)
1.0m/s(200LFM)
1.5m/s(300LFM)
• All specifications are subject to change without notice.
002-02 / 20040525 / ea33_br_ihad.fm