Note: Inclusive of initial frequency accuracy, operating temperature range, supply variation, load variation, 3 times solder reflow, shock, vibration and 1 year aging at 25°C. We do not
recommend hand soldering the devices
JUNE 20, 2017
3
IDT XO HCSL CRYSTAL OSCILLATOR
XUN DATASHEET
DC Characteristics
(V
DD
= 2.5V
±5%, T
A
= - 20°C to +70°C; -40° to +85°C). Below are guaranteed for listed standard frequencies.
Parameter
Power Supply Current
Output HIGH Voltage
Output LOW Voltage
Enable/Disable Input HIGH Voltage
(Output enabled)*
Enable/Disable Input LOW Voltage
(Output disabled)
Symbol
I
DD
V
OH
V
OL
V
IH
V
IL
Condition
Standard frequencies
Std HCSL load
Std HCSL load
Min
0.55
0
70%V
DD
Typ
Max
102
0.95
0.2
Units
mA
V
V
V
30%V
DD
V
* A pullup resistor from pin 6 (VDD) to pin 1 (E/D) enables output when pin 1 is left open.
AC Characteristics
(V
DD
= 2.5V
±5%, T
A
= - 20°C to +70°C; -40° to +85°C). Below are guaranteed for listed standard frequencies.
Note: Inclusive of initial frequency accuracy, operating temperature range, supply variation, load variation, 3 times solder reflow, shock, vibration and 1 year aging at 25°C. We do not
recommend hand soldering the devices
IDT XO HCSL CRYSTAL OSCILLATOR
4
JUNE 20, 2017
XUN DATASHEET
DC Characteristics
(V
DD
= 1.8V
±5%, T
A
= - 20°C to +70°C; -40° to +85°C). Below are guaranteed for listed standard frequencies.
Parameter
Power Supply Current
Output HIGH Voltage
Output LOW Voltage
Enable/Disable Input HIGH Voltage
(Output enabled)*
Enable/Disable Input LOW Voltage
(Output disabled)
Symbol
I
DD
V
OH
V
OL
V
IH
V
IL
Condition
Standard frequencies
Std HCSL load
Std HCSL load
Min
0.45
0
70%V
DD
Typ
Max
68
0.7
0.2
Units
mA
V
V
V
30%V
DD
V
* A pullup resistor from pin 6 (VDD) to pin 1 (E/D) enables output when pin 1 is left open.
AC Characteristics
(V
DD
= 1.8V
±5%, T
A
= - 20°C to +70°C; -40° to +85°C). Below are guaranteed for listed standard frequencies.
Note: Inclusive of initial frequency accuracy, operating temperature range, supply variation, load variation, 3 times solder reflow, shock, vibration and 1 year aging at 25°C. We do not
The COVID-19 pandemic, which has prompted the need for social distancing and staggered work hours, has forced us to rethink the use and lighting of office, manufacturing, retail and hospitality spaces...
I still remember the DIY work video of Mr. He shared on the forum not long ago. At the end of the video, there was an advertisement for the sponsor company. At that time, I thought this company was go...
The photoelectric-contact liquid level sensor is a sensor that outputs analog signals. Its application circuit is shown in Figure 1.Figure 1 Application circuit
During the detection process, the outpu...
This article is to make up for the previous review, which I forgot to continue. Today, I will continue to test our Alibaba Cloud connection.
For more information, please refer to the previous review, ...
I am willing to use key interrupts, as I believe that every action can be avoided. However, in actual work, this is sometimes not necessarily a good thing, and in some sense is a bad thing.
I looked a...