EEWORLDEEWORLDEEWORLD

Part Number

Search

MDU13H-4M

Description
TRIPLE, ECL-INTERFACED FIXED DELAY LINE (SERIES MDU13H)
Categorylogic    logic   
File Size27KB,4 Pages
ManufacturerData Delay Devices
Environmental Compliance
Download Datasheet Parametric View All

MDU13H-4M Overview

TRIPLE, ECL-INTERFACED FIXED DELAY LINE (SERIES MDU13H)

MDU13H-4M Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerData Delay Devices
Parts packaging codeDIP
package instructionDIP-16/9
Contacts16/9
Reach Compliance Codecompli
JESD-30 codeR-XDIP-T9
length20.32 mm
Logic integrated circuit typeACTIVE DELAY LINE
Number of functions3
Number of taps/steps1
Number of terminals9
Output characteristicsOPEN-EMITTER
Output polarityTRUE
Package body materialUNSPECIFIED
encapsulated codeDIP
Package shapeRECTANGULAR
Package formIN-LINE
Peak Reflow Temperature (Celsius)NOT SPECIFIED
programmable delay lineNO
Certification statusNot Qualified
Maximum seat height8.636 mm
surface mountNO
technologyECL
Terminal formTHROUGH-HOLE
Terminal pitch2.54 mm
Terminal locationDUAL
Maximum time at peak reflow temperatureNOT SPECIFIED
Total delay nominal (td)4 ns
width7.62 mm
MDU13H
TRIPLE, ECL-INTERFACED
FIXED DELAY LINE
(SERIES MDU13H)
FEATURES
Three independent delay lines
Fits standard 16-pin DIP socket
Auto-insertable
Input & outputs fully 10KH-ECL interfaced & buffered
GND
1
16
15
14
13
I1
I2
I3
VEE
5
6
7
8
O1
O2
O3
data
3
®
delay
devices,
inc.
PACKAGES
GND
GND
N/C
N/C
N/C
I1
I2
I3
VEE
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
GND
O1
O2
O3
N/C
N/C
N/C
N/C
MDU13H-xx DIP
MDU13H-xxM Military DIP
MDU13H-xxC3 SMD
MDU13H-xxMC3 Mil SMD
FUNCTIONAL DESCRIPTION
The MDU13H-series device is a 3-in-1 digitally buffered delay line. The
signal inputs (I1-I3) are reproduced at the outputs (O1-O3), shifted in time
by an amount determined by the device dash number (See Table). The
delay lines function completely independently of each other.
PIN DESCRIPTIONS
I1-I3
O1-O3
VEE
GND
Signal Inputs
Signal Outputs
-5 Volts
Ground
SERIES SPECIFICATIONS
Minimum input pulse width:
50% of total delay
Output rise time:
2ns typical
Supply voltage:
-5VDC
±
5%
Power dissipation:
200mw typical (no load)
Operating temperature:
-30° to 85° C
Temp. coefficient of total delay:
100 PPM/°C
DASH NUMBER SPECIFICATIONS
Part
Number
MDU13H-3
MDU13H-4
MDU13H-5
MDU13H-10
MDU13H-15
MDU13H-20
MDU13H-25
MDU13H-30
MDU13H-35
MDU13H-40
MDU13H-45
MDU13H-50
Delay Per
Line (ns)
3
±
1.0
4
±
1.0
5
±
1.0
10
±
1.0
15
±
1.0
20
±
1.0
25
±
2.0
30
±
2.0
35
±
2.0
40
±
2.0
45
±
2.2
50
±
2.5
O1
O2
O3
100%
100%
100%
* Total delay is referenced to first tap output
Input to first tap = 1.5ns
±
1ns
NOTE: Any dash number between 3 and 50
not shown is also available.
VCC
I1
I2
I3
GND
Functional block diagram
©
1997 Data Delay Devices
Doc #97037
12/11/97
DATA DELAY DEVICES, INC.
3 Mt. Prospect Ave. Clifton, NJ 07013
1

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号