-48V Hot-Swap Controllers
with External R
SENSE
MAX5949A/MAX5949B
ABSOLUTE MAXIMUM RATINGS
(All voltages are referenced to V
EE
, unless otherwise noted.)
Supply Voltage (V
DD
- V
EE
) .................................-0.3V to +100V
PWRGD,
PWRGD
.................................................-0.3V to +100V
DRAIN (Note 1)........................................................-2V to +100V
PWRGD to DRAIN .............................................… -0.3V to +95V
PWRGD to V
DD
........................................................-95V to +85V
SENSE (Internally Clamped) .................................-0.3V to +1.0V
GATE (Internally Clamped) ....................................-0.3V to +18V
UV and OV..............................................................-0.3V to +60V
Current Through SENSE ...................................................±40mA
Current into GATE...........................................................±300mA
Current into DRAIN .........................................-100mA to +20mA
Current into Any Other Pin................................................±20mA
Continuous Power Dissipation (T
A
= +70°C)
8-Pin SO (derate 5.9mW/°C above +70°C)..................471mW
Operating Temperature Range ...........................-40°C to +85°C
Junction Temperature .....................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
Soldering Temperature (reflow) .......................................+260°C
Note 1:
Test condition per Figure 1. DRAIN current must be limited to the specified 100mA maximum.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
[align=center][/align] [size=4]Recently, 996 has suddenly become a hot topic. Jack Ma and Liu Qiangdong have both started to ask their employees to work 996. Huawei has already implemented 996. Jack M...
Theoretically, the amplification factor should be 330 times. When 0.1A current flows through the sampling resistor R5, the output should be around 3.3V. Why is the output always around 4.7V when using...
After the mature smart grid is built, smart meters will have the functions of automatic query and remote meter reading, and can also realize automatic power off. However, at present, domestic smart me...
Considering that many oscilloscope users don't know how to connect their phones to the oscilloscope, I made this video to explain in detail. The video content includes the connection methods of the ST...