44A30-07-1-03N

Description
Rotary Switches 44A30-07-1-03N r lug, 30u0026deg;, 6 deck, 1 pole/deck, 12 positions/pole, non-shorting, fixed stop, 44A30-06B12N
CategoryMechanical and electronic products    switch   
File Size433KB,4 Pages
ManufacturerGrayhill
Websitehttp://www.grayhill.com
Environmental Compliance
Download Datasheet Parametric View All

44A30-07-1-03N Online Shopping

Suppliers Part Number Price MOQ In stock  
44A30-07-1-03N - - View Buy Now

44A30-07-1-03N Overview

Rotary Switches 44A30-07-1-03N r lug, 30u0026deg;, 6 deck, 1 pole/deck, 12 positions/pole, non-shorting, fixed stop, 44A30-06B12N

44A30-07-1-03N Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerGrayhill
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Factory Lead Time16 weeks
Actuator typeSINGLE SHAFT TYPE
body height85.16 mm
Body length or diameter29.51 mm
Contact (AC) maximum rated R load1A@115VAC
Maximum contact current (AC)1 A
Maximum contact current (DC)1 A
Contact (DC) maximum rated R load1A@28VDC
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Electrical life6000 Cycle(s)
Graduation angle30 deg
JESD-609 codee3
Installation featuresPANEL MOUNT
Number of positions3
Number of switching segments7
surface mountNO
Switch actionLATCHED
switch functionSP3T
Switch typeROTARY SWITCH
Terminal surfaceTin (Sn)
Termination typeSCREW
Base Number Matches1
Special Function Rotary Switches
SERIES 08,09,42,44,50
Spring Return
FEATURES
• Hold-To-Test, Hold-To-Calibrate,
And Other Momentary Applications
• Choice of Configurations, Ratings,
Styles and Circuitry
• 10,000 Cycles of Operation
DESCRIPTION
A spring return rotary switch has 1 or more momentary positions. Maintaining contact at momentary
positions requires rotational force. Releasing the force allows the mechanism to return the contact
to a normal, or detent, position.
DIMENSIONS
Series 08 & 09
DIM. A + .046 (1,17)
–.020 (0,51)
DIM. B REF.
STUD PROJECTION
Series 50
Equivalent to Series 50 Standard Switches
.500 ± .015
(12,7 ± 0,38)
DIA.
.320 ± .015 (8,13 ± 0,38)
CIRCLE OF CENTERS
COMMON
36°
± 3°
For all other dimensions and
specifications, see Standard
Switch pages.
No. of
Decks
1
2
3
4
5
6
Dim
A
.960
1.228
1.496
1.764
2.032
2.550
(24,38)
(31,19)
(38,0)
(44,81)
(51,61)
(64,77)
Dim
B
.062
.062
.062
.062
.062
.312
(1,57)
(1,57)
(1,57)
(1,57)
(1,57)
(7,92)
Series 42 & 44
DIM. A + .046 (1,17)
–.020 (0,51)
Rotary Switches
No. of
Decks
1
2
3
Dim.
A
1.025 (26,04)
1.371 (34,82)
1.717 (43,61)
For all other dimensions and
specifications, see Standard
Switch pages.
For all other dimensions and
specifications, see Standard
Switch pages.
CONFIGURATIONS
This configuration indicates a counterclockwise
force is required to hold the switch at position
#1. “M” indicates a momentary position
counterclockwise of “D” and "D", detented ones.
Positions
1
2
3
M D
D
Releasing this force breaks contact with position
#1 and returns the switch to #2. Normal rotary
switch detent action occurs when the switch is
rotated between position #2 and #3.
All of the configurations (except
MDM)
list a
basic 2 position arrangement which is shown in
italics. Example:
MDDDDD
or DDDDDM. Several
positions can be added during the switch
construction at the factory; but, any configuration
must always contain the 2 basic positions.
SELECTING A SWITCH
1. Select a Configuration:
The total number of
positions always includes the 2 basic positions.
A (4) position switch of DDDDM configuration
would have 3 detent positions counterclockwise
of the momentary position.
2. Select Series, Angle of Throw, and Style:
See the Choices Chart. The basic switch
description, series, and throw are as follows:
1
/
2
",
1
/
4
Amp, multi-deck
08 = 36° 09 = 30°
1", 1 Amp, multi-deck
42 = 36° 44 = 30°
1
/
2
", 200 mA, single deck 50 = 36°
Electrical ratings are the same as those of the
conventional switches with the exception of life.
Life is limited to 10,000 cycles of operation
(25,000 cycles for Series 50) due to the spring
arrangement. Dimensions are the same as for
conventional types except for the shaft flat
orientation of the 3, 4, 5, and 6 pole, Series 09
and 44 in the DDDDDM configuration (see
chart).
3. Select Poles & Positions Per Pole:
If you
do not find the poles and positions per pole you
need in one series, try another or contact the
factory. If the behind panel length is a problem,
select a multi-pole type instead of a single deck.
OPTIONS
Watertight panel seal; Multi-pole switches that
exceed the limits noted in the Selector Chart;
Series 50
MD
or
DM
configurations in Military
styles; Series 08, 09, & 44 in MMMDM MM, and
in MMDD MM, and in MMMMMD.
Not available through Distributors
ORDERING INFORMATION
Create the part number using this example.
Stem number from chart
(4 or 5 digits)
Number of Decks
Number of Poles/Deck
093103-2-045
Type of Contacts:
S=Shorting
N=Non-Shorting
Number of Positions/Pole
Exception: Numbers beginning with 5 are
already complete part numbers.
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
iTOP-3399 development board Linux system compilation and burning - obtain/install/compile Linux source code
6.1 Get the x Linux source code (based on Xunwei iTOP-399 development board)First download the Linux source code provided by Xunwei from the network disk. The source code file directory obtained after...
塔7呃 Embedded System
Questions about writing data from DSP to DATARAM in PRU1
[size=4]1.PRU adopts assembly programming, and uses C6748 to write an integer data 1234 into the DATA RAM (0x01C30000) of PRU1. PRU1 obtains the data in RAM (C3) and processes it (doubles it). After t...
fish001 Microcontroller MCU
The weekly evaluation information will be here soon~ Have a happy holiday and happy work~~
After a long vacation, our evaluation information is open again~~~ Come and see what evaluation activities are in the application period and what evaluation reports are freshly released~~Evaluation ac...
okhxyyo Special Edition for Assessment Centres
Crazy Shell AI open source drone PID basics
1. Introduction to PID PID control is the most commonly used control method in automatic control systems. It was created mainly to solve the problems of fast, stable and accurate automatic control sys...
fengke Creative Market
What are the main differences between DSP's C language and host's C language?
1) The C language of DSP is standard ANSI C, which does not include the extended parts that communicate with peripherals, such as screen drawing, etc. However, in CCS, in order to facilitate debugging...
火辣西米秀 DSP and ARM Processors
renesas Renesas R-CAR Series Guide
"R-Car" is the nickname for Renesas' family of system-on-chip (SoC) designed for next-generation automotive computing in the era of self-driving cars, for use in automotive information systems. The sc...
zoezou Automotive Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号