EEWORLDEEWORLDEEWORLD

Part Number

Search

QASP5M220AL

Description
Time Delay u0026 Timing Relays TMR 12
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size619KB,3 Pages
ManufacturerCrouzet
Download Datasheet Parametric View All

QASP5M220AL Online Shopping

Suppliers Part Number Price MOQ In stock  
QASP5M220AL - - View Buy Now

QASP5M220AL Overview

Time Delay u0026 Timing Relays TMR 12

QASP5M220AL Parametric

Parameter NameAttribute value
Product CategoryTime Delay & Timing Relays
ManufacturerCrouzet
Factory Pack Quantity1
TIMERS
TIMERS
GENERAL DETAILS
OF TYPE Q TIMERS
Q series timers are compact, low cost, precision devices designed to the most demanding
specifications. The small size, epoxy filled case is highly resistant against dust, vibrations,
shock and humidity. Creep and strike distance according to VDE 0110 Group C 250V. Case
protection IP66. Case material - Phenolic.
1.30
(33.2 mm)
2.00
(50.8mm)
.75
(19.05 mm)
2.00
(50.8mm)
2
250
(16.35 mm)
250 DIA. MALE QUICK CONNECT TERMINALS
(16.35 mm)
QAS SERIES
DELAY ON MAKE
ELECTRONIC TIMER
UL listed
CSA recognized
Function A:
Delay on Make
Input Power S1
Output
0
T
SPECIFICATIONS:
Input Power
. . . . . . . . . . . . . . . . . 24 VAC/DC, 110 VAC/DC
220 VAC/DC ±15%, 50/60 Hz
Output Rating
. . . . . . . . . . . . . . . max.:
1.0
A at 20°C
min.: 10 mA
Voltage drop after timing
. . . . . . 3.5 VAC/DC
Repetition accuracy
. . . . . . . . . . ±0.5% at a constant ambient
Temp rise derating
. . . . . . . . . . . 5 mA / °C
Reset time SAS & SAS-D
. . . . . . 25 ms after timing
50 ms during timing
Leakage current during timing
. . 5 mA max
Peak surge current
. . . . . . . . . . . 20 A < 10 ms
Peak surge voltage
. . . . . . . . . . . 1400 V, 10 µs
Terminals
. . . . . . . . . . . . . . . . . . . 1/4˝ (6.35mm) quick connect
Operating temperature
. . . . . . . . -22°F to +140°F (-30°C to +60°C)
Weight
. . . . . . . . . . . . . . . . . . . . . 1.9 oz. (55g)
Peak Surge Current
Function A: When input power is applied, timing (t) begins. At the end
of the preselected time, the solid state SCR output turns on. The out-
put turns off when the input power is removed, resetting the timer for
the next cycle.
WIRING DIAGRAM:
QAS
QAS-D
470K
R
T
1
100A
50A
20A
15A
10A
5A
Peak Surge Current vs Surge Current Duration
3
1
3
+
-
˜
++
--
LOAD
˜˜
+
-
LOAD
˜
INPUT
2A
1A
10ms 20ms 50ms 100ms 200ms 500ms
1s 2s 5s
Surge Current Duration
INPUT
Note:
Available with internal potentiometer in AS-P Series
ORDERING INFORMATION: (100 pcs. minimum)
P.S.:
Specify maximum time for “D” and “P” version.
Q
MOUNTING
AS-D
SERIES
100S
TIME RANGE
220 AD
INPUT POWER
L
UL
Q
= Encapsulated
AS
= fixed time
AS-D
= remote potentiometer
AS-P
= internal potentiometer
AS
= Fixed .1 sec - 120 min
AS-D
= .1 sec - 60 min. 10:1 Ratio
AS-P
= .1 sec - 10 sec
1-100 sec maintain 100:1 ratio
24AD
= 24 VAC/DC
110AD
= 110 VAC/DC
220AD
= 220 VAC/DC
1 AMP
Products and specifications subject to change without notice.
2/46a
Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号