DataSheet
SeriesOne DR Series
ATEX
AC
DC
DIN Rail Mount
•
Ratings 3 Amps
•
Load voltage ratings of 1-60 VDC, 1-100 VDC, 24-280 VAC and 48-600 VAC
•
Fits standard 35mm DIN Rail
•
LED input status indicator
•
AC or DC control
•
Zero Voltage (resistive loads) or Instantaneous (inductive loads) turn-on output
•
UL 508 Endurance Rating for Enhanced Reliability
•
UL Class I and II, Division 2, for Hazardous Locations
PRODUCT SELECTION
Control Voltage
4-32 VDC
90-140 VAC
200-280 VAC
18-36 VAC
280V, 3 A
DR24D03X
DR24B03X
DR24A03X
DR24E03X
600V, 3 A
DR48D03X
60V, 3 A
DR06D03X
100V, 3 A
DR10D03X
AVAILABLE OPTIONS
Operating Voltage
06:
1-60 VDC
10:
1-100 VDC
24:
24-280 VAC
48:
48-600 VAC
Switching Type
Blank:
Zero Voltage Turn-On
(AC Output Only)
R:
Instantaneous Turn-On
(AC Output)
Series
Rated Load Current
03:
3 Amps
DR
06
D
03
X
R
Agency Approvals
Control Voltage
X:
ATEX II 3G Ex nA IIC T4 Gc
D:
4-32 VDC
approved
A:
200-265 VAC
AC
Output
B:
90-140 VAC
Only
E:
18-36 VAC
(1)
Required for valid part number
For options only and not required for valid part number
OUTPUT SPECIFICATIONS AC Output
(2)
Description
Operating Voltage
(3)
Transient Overvoltage [Vpk]
Maximum Load Current, resistive
(4)
Minimum Load Current
Maximum Off-State Leakage Current @ Rated Voltage [mA]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/
µ
sec]
(5)
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Maximum Surge Current (50/60Hz, 1 cycle) [Apk]
Maximum I²t for Fusing (50/60 Hz, 1/2 cycle) [A² sec]
HP Rating UL 508/IEC60947 [HP (KW)] @ 240V
HP Rating UL 508/IEC60947 [HP (KW)] @ 380V
HP Rating UL 508/IEC60947 [HP (KW)] @ 480V
Minimum Power Factor (at Maximum Load)
Min/Max stranded wire
Min/Max solid wire
Weight (Typical)
DR24x03X
24-280 Vrms
600
3 Arms
150 mArms
0.1
500
1.3
285/300
410/375
1/4 (.18)
N/A
N/A
0.5
22/14 AWG
22/14 AWG
1.76 oz. (50g)
DR48x03X
48-600 Vrms
1200
3 Arms
150 mArms
0.1
500
1.3
285/300
410/375
1/4 (.18)
1/3 (.25)
1/2 (.37)
0.5
22/14 AWG
22/14 AWG
1.76 oz. (50g)
DR06D03X
1-60 VDC
N/A
3
2.5 mAdc
0.1
N/A
0.6
60
N/A
N/A
N/A
N/A
N/A
22/14 AWG
22/14 AWG
1.76 oz. (50g)
DR10D03X
1-100 VDC
N/A
3
2.5 mAdc
0.1
N/A
0.6
60
N/A
N/A
N/A
N/A
N/A
22/14 AWG
22/14 AWG
1.76 oz. (50g)
Do not forget to visit us at:
www.crydom.com
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.
DataSheet
INPUT SPECIFICATIONS
(2)
Description
Control Voltage Range
(6)
Minimum Turn-On Voltage
Must Turn-Off Voltage
Minimum Input Current for [mA]
(7)
Maximum Input Current for [mA]
(7)
Maximum Turn-on Time [msec]
(8) (9)
Maximum Turn-off Time [msec]
(10)
Min/Max stranded/solid wire
DIN Rail Mount
DRxxExxX
18-36 Vrms
(1)
18 Vrms
4 Vrms
3.5
8
20 msec
30 msec
22/16 AWG
DRxxDxxX
4-32 VDC
4.0 VDC
1.0 VDC
9
11
1/2 Cycle
1/2 Cycle
22/16 AWG
DRxxBxxX
90-140 Vrms
90 Vrms
10 Vrms
3
5
20 msec
30 msec
22/16 AWG
DRxxAxxX
200-265 Vrms
200 Vrms
40 Vrms
2.5
3.3
20 msec
30 msec
22/16 AWG
GENERAL SPECIFICATIONS
(1)
Description
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 VDC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Recommended Terminal Screw Torque Range
Parameters
4000 Vrms
(11)
10
9
Ohm
10 pF
-20 to 40 °C
-30 to 100 °C
4.4-7.0 in-lb (0.5-0.8Nm)
GENERAL NOTES
(1)
E option is UL certified for AC control voltage, but it works also with 18-36 VDC input range.
(2)
All parameters at 25°C unless otherwise specified.
(3)
For AC output frequency is 47-63Hz
(4)
See Derating curves
(5)
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
(6)
DC control includes reverse polarity protection.
(7)
Input circuitry incorporates active current limiter.
(8)
Turn-on time for DC control random turn-on versions is 0.1 msec.
(9)
Turn-on time for DC output 600
µsec
.
(10)
Turn-off time for DC output 300
µsec
.
(11)
2500 Vrms for DC output.
Standards of Compliance
IEC 62314
LC A, Resistive or Slightly Inductive Load Ratings: 3 A @40°C ambient for DR24x03X, 3 A @ 40°C ambient for DR48x03X
LC B, Motor Loads Ratings: 0.18KW @ 240VAC for DR24x03X and 0.375KW @ 480 VAC DR48x13X
Shock and Vibration
(Applies to all part numbers)
Vibration Resistence according to IEC 60068-2-6:
0.35mm and 0.75mm Amplitude over 10-55 Hz
Shock Resistance according to IEC 60068-2-27:
15g/11ms
EMC
(Applies to all part numbers)
IEC 61000-4-2: Electrostatic Discharge- Level 3
IEC 61000-4-4: Electrically Fast Transients- Level 3
IEC 61000-4-5: Electrical Surges- Level 3
ANSI / ISA 12.12.01-2013
Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Division 1 and 2 Hazadous (classified) locations
This equipment is open-type device and is meant to be installed in an enclosure suitable for the enviroment such that the equipment is only accesible with the use of a tool
suitable for use in Class 1, Division 2, Group A,B,C and Hazardous locations, or Nonhazardous locations only
WARNING-Explosion Hazard- Do not disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations
WARNING-Explosion Hazard- Substitution of any component may impair suitability for class I, Division 2
ATEX
Compliance with Essential Health and Safety Requirements has been assessed by reference to Standards EN 60079-0:2012+A11:2013
and EN 60079-15-:2010
Do not forget to visit us at:
www.crydom.com
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.