Isolated DC/DC Converters VI J00/200 - 150 Vin, 36 Vout, 100 W, E Product Grade
CategoryPower/power management    The power supply circuit   
File Size655KB,8 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Environmental Compliance
Download Datasheet Parametric View All

VE-J5J-EW-F1 Online Shopping

Suppliers Part Number Price MOQ In stock  
VE-J5J-EW-F1 - - View Buy Now

VE-J5J-EW-F1 Overview

Isolated DC/DC Converters VI J00/200 - 150 Vin, 36 Vout, 100 W, E Product Grade

VE-J5J-EW-F1 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerVICOR
Reach Compliance Codecompliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage200 V
Minimum input voltage100 V
Nominal input voltage150 V
JESD-30 codeR-XDMA-P9
JESD-609 codee3
Maximum load regulation0.5%
Number of functions1
Output times1
Number of terminals9
Maximum operating temperature100 °C
Minimum operating temperature-10 °C
Maximum output voltage39.6 V
Minimum output voltage18 V
Nominal output voltage36 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelOTHER
Terminal surfaceMATTE TIN OVER NICKEL
Terminal formPIN/PEG
Terminal locationDUAL
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output100 W
Fine-tuning/adjustable outputYES
Half Brick, DC-DC Converters
VI-J00
VE-J00
®
S
C
US
C
NRTL
US
25 to 100 Watts
Features & Benefits
Isolated output
Up to 50W/in
3
cURus, cTÜVus
CE Marked
Up to 90% efficiency
Size: 2.28” x 2.4” x 0.5”
(57,9 x 61,0 x 12,7mm)
Remote sense and current limit
Logic disable
Wide range output adjust
ZCS power architecture
Low noise FM control
RoHS compliant (VE verisons)
Product Highlights
The VI-J00 MiniMod family established a new standard in component-level DC-DC
converters. This “junior” size complement to the higher power VI-200 family offers up
to 100W of isolated and regulated power in a board mounted package. With thousands
of input/output/power combinations, and with a maximum operating temperature
rating of 100°C, the MiniMod provides nearly unlimited flexibiliy for power system
designers to meet demanding time to market requirements.
Utilizing Vicor’s “zero-current-switching” forward converter technology, proven
by an installed base of over 8 million units, the MiniMod family combines state of
the art power density with the efficiency, low noise and reliability required by next
generation power systems.
Part Numbering
VI
J
6
1
C
W
Family
VI
=Non-RoHS
VE
= RoHS
Series
J
= J00
0
= 12V
V
= 24V
1
= 24V
W
= 24V
2
= 36V
3
= 48V
Input
N
= 48V
4
= 72V
T
= 110V
5
= 150V
6
= 300V
7
= 150/300V
Z
= 2V
Y
= 3.3V
0
= 5V
X
= 5.2V
W
= 5.5V
V
= 5.8V
T
= 6.5V
R
= 7.5V
Output
M
= 10V
1
= 12V
P
= 13.8V
2
= 15V
N
= 18.5V
3
= 24V
L
= 28V
J
= 36V
K
= 40V
4
= 48V
H
= 52V
F
= 72V
D
= 85V
B
= 95V
Grade
E
= –10 to 100°C
I
= – 40 to 100°C
M
= –55 to 100°C
≥ 5V
Power
< 5V
W
= 20A
X
= 15A
Y
= 10A
Z
= 5A
C
= –25 to 100°C
W
= 100W
X
= 75W
Y
= 50W
Z
= 25W
Note:
For additional
packaging options,
please see page 5.
VI-J00 DC-DC Converters
Page 1 of 7
Rev 3.0
06/2017
[Evaluation of EC-01F-Kit, the NB-IoT development board of Essence] 03. Discussion: Frequent disconnection after the device is connected to the network
[i=s]This post was last edited by Li Baiyi on 2021-12-22 21:11[/i]When debugging EC-01F MQTT to access Alibaba, the normal communication state is frequently disconnected and then automatically connect...
李百仪 RF/Wirelessly
If you use tweezers to short-circuit the output of a power supply, how many states will the load have?
At the moment the tweezers are short-circuited, the load becomes 0. At the moment the tweezers are released, the load changes from 0 back to its original value. Is this change process completed instan...
sfcsdc Analog electronics
Can a relay that switches on and off frequently be connected to a transformer?
I have a heating wire that is AC 70V, so I need a 220V to 70V transformer. The temperature control module is a relay output model, with a heating wire of 800W and a transformer of 3KVA. Now it is not ...
魔双月壁 Power technology
What tests need to be done before using power electronic products such as motor controllers after they have been stored for a long time?
Power electronic device integrated products, such as motor controllers, are stored for a long time (under non-strict storage conditions, such as humidity and temperature), and need to be used again. W...
zimiaoxinghan Power technology
Receiver system design
Block diagram of a generic superheterodyne receiver....
btty038 RF/Wirelessly
EEWORLD University Hall ---- Electrical Engineering North China Electric Power University Li Yonggang
Electrical Engineering North China Electric Power University Li Yonggang : https://training.eeworld.com.cn/course/5999Electrical Engineering North China Electric Power University Li Yonggang...
抛砖引玉 Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号