* Not CE certified for the EU"
TR36 SERIES
36W SWITCHING
ADAPTER
Features
* Universal Input Range 90-264VAC
* Meets EN55022 Class B and
CISPR/FCC Class B, Conducted
* Continuous Short Circuit Protection
* Leakage Current 0.25mA Max.
* Over Voltage Protection
* PSE Mark is Option
Ordering information
TR36AXX-
Model No.
XX
DC Plug Type
*Please see Page213 for
more detailed descriptions
X
OVP Option
A: Without OVP Option
E: With OVP Option
XX
DC Cable Length and Type
01: 720mm
02: 1200mm
03: 1800mm
11: 720mm with Ferrite Core
12:1200mm with Ferrite Core
13:1800mm with Ferrite Core
*18AWG/UL1185
OUTPUT
MODEL
VOLTAGE
MIN.
LOAD
OUTPUT
CURRENT
RIPPLE &
NOISE
VOLTAGE
REGULATION
LINE
REGULATION
LOAD
REGULATION
% EFF.
(Typ.
68%
76%
78%
80%
80%
81%
81%
83%
TR36A05
TR36A09
TR36A12
TR36A13
TR36A15
TR36A18
TR36A24
TR36A48
5V
9V
12V
13.5V
15V
18V
24V
48V
0
0
0
0
0
0
0
0
4.0A
3.0A
2.5A
2.4A
2.4A
2.0A
1.5A
0.75A
1%
1%
1%
1%
1%
1%
1%
1%
±2%
±2%
±2%
±2%
±2%
±2%
±2%
±2%
±
1%
±
1%
±
1%
±
1%
±
1%
±
1%
±
1%
±
1%
±
6%
±
5%
±
5%
±
5%
±
3%
±2
%
±2
%
±2
%
1
Specifications
INPUT SPECIFICATIONS:
Voltage …....………........…........................................... 90~264Vac
Frequency ………………………………………….……………..... 50 to 60Hz
Inrush Current ………………….………….................... 60A max. @240Vac
Leakage Current …………………………………………….…… 0.25mA max.
TR36 Series Derating Curve
100%
Rated Load(%)
80%
60%
40%
20%
0%
0
10
20
30
40
Ambient Temperature(
o
C)
50
60
20LFM(Natural Convection)
OUTPUT SPECIFICATIONS:
Holdup Time ……………………………………………… 8ms typ. @115Vac
Short Circuit Protection …………….…………… Continuous(Auto Recover)
Over Voltage Protection …………………………..TVS Component to Clamp
Temperature Coefficient ……………………................................ ±0.05%/℃
NOTE:
1. Voltage setpoint at 60% load
2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
Ripple & Noise measuring @20MHz BW.
3. Line regulation is measured from 100Vac to 240Vac, full load.
4. Load regulation measured from 60% to 100% full load and from 60%
to 20% load (60% +/- 40% full load)
5. ”Various TR Series adapters are PSE certified. PSE certification
alone is not sufficient for importation into Japan. A valid PSE mark
must contain the name of the importer as shown in the example below.
If PSE mark is required, the name of the registered importer must be
supplied to Cincon on order placement. Product labels will not contain
PSE mark if importer name is not supplied. Consult factory or local
representative for details”
GENERAL SPECIFICATIONS:
Isolation …………………………………………… Input to output = 4,242VDC
Operating Temperature ................................... 0 ~ 60℃(see derating curve)
Storage Temperature ……………………………….........……........ -20~85℃
Humidity ....................................................... 93% RH max. Non condensing
Cooling …………………………………………….……… Natural Convection
Switching Frequency …………………………….….……. 50~70KHz Typical
MTBF ….…… MIL-HDBK-217F, GB, at 25℃/115VAC ……… 200K hrs min.
Altitude ……………………..…...……………………………………… 2000m
Dimensions …….…….. 4.331x1.969x0.787inches(110.00x50.00x20.00mm)
Weight ……………………………………………………… 190g(0.42 Pounds)
AC Inlet …………………………………………………………….. IEC320/C8
SAFETY AND EMC:
Emission and Immunity ……....…. EN55022 Class B, FCC Part 15 Class B
EN61000-3-2, EN61000-3-3, EN55024
Safety ……………….…………..…… IEC60950-1, EN60950-1, UL60950-1
Mechanical Specification
All Dimensions are in inches(mm)
Tolerance:Inches:X.XXX±0.02
Millimeters:X.XX±0.5
4.331[110.00]
70.866[1800.00]±1.969[50.00]
1.969[50.00]
IEC320/C8
0.787[20.00]
DC Plug type: V+ ─●)─ V-
DC Plug:Right Angle(ψ5.5/ψ2.5 )L12mm
18AWG/1800mm
Typical at 25℃, nominal line and 75% load, unless otherwise Specified
2