Min. 100MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
1,000 Vrms for 1min. (Detection current: 10mA.)
1,000 Vrms for 1min. (Detection current: 10mA.)
2,000 Vrms for 1min. (Detection current: 10mA.)
Max. 20ms
Max. 10ms
2
Between
contact and coil
Operate time (at 20°C
68°F)
Release time (at 20°C
68°F)
Shock
resistance
Vibration
resistance
Functional
Destructive
Functional
Destructive
Max. 20ms
Mechanical
characteristics
Expected life
Conditions
Unit weight
Max. 10ms
Min. 98 m/s (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Min. 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 2 mm
Min. 5×10
7
Min. 5×10
7
–40°C to +55°C
–40°F to +131°F
18 g
.63 oz
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10μs.)
Mechanical
Conditions for operation,
transport and storage*
2
(Not freezing and condensing
at low temperature)
–40°C to +70°C
–40°F to +158°F
(Max.48V DC),
–40°C to +55°C
–40°F to +131°F
(100V DC)
16 g
.56 oz
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
3. Electrical life
Condition: Resistive load
Types
Standard type
2 Form C
Sealed type
Standard type
4 Form C
Sealed type
Switching capacity
5A 30V DC
5A 250V AC
5A 30V DC
3A 250V AC
5A 30V DC
4A 250V AC
5A 30V DC
2A 250V AC
No. of operations
Min. 5×10
5
Min. 1×10
5
Min. 5×10
5
Min. 1×10
5
Min. 5×10
5
Min. 1×10
5
Min. 5×10
5
Min. 1×10
5
–4–
ASCTB12E 201701-T
NC
REFERENCE DATA (Standard type)
1.-(1) Life curve (2 Form C, 4 Form C)
10,000
110 V DC resistive
Expected life,
×10
4
Expected life,
×10
4
Expected life,
×10
4
1,000
1,000
125 V AC resistive
250 V AC resistive
125 V AC inductive (pf=0.4)
250 V AC inductive (pf=0.4)
1.-(2) Life curve (2 Form C)
5,000
1.-(3) Life curve (4 Form C)
5,000
1,000
250 V AC resistive
250 V AC inductive (pf=0.4)
100
100
100
220 V DC resistive
30 V DC resistive
10
0.1
1.0
10
0
1
2
3
4
5
10
0
1
2
3
4
5
Contact carrying current, A
Contact carrying current, A
Contact carrying current, A
2. Temperature rise characteristics
(single side stable)
Measured portion: Inside the coil
Temperature rise,
°C
rre
nt)
3. Operate time (single side stable)
4. Release time (single side stable)
80
70
60
50
40
30
20
Operate time, ms
14
12
10
8
6
4
2
80
100
90
110
Coil applied voltage,%V
Max.
Max.
Min.
Min.
Release time, ms
c
u
ct
gc
nta
rrin
Co
t ca
(
ac
3 A
(Cont
tac
nt)
on
A
urre
5
(C
gc
n
arri
5A
ct c
nta
(Co
3A
tc
in
arr
gc
u
in
arr
u
gc
rre
nt)
t)
rren
20
18
16
4c
2c
5
4c
2c
4
3
Max.
Min.
Max.
Min.
4C
2C
0.4
0.6 0.8 1.0 1.2 1.4 1.6 1.8W
180
200
220%V
2
Operating
power
Coil voltage
up to
(
2C : 48 V DC
)
2C : 100 V DC
(
4C : all types
)
1
100 120 140 160
100 110 120 130 140 150%V
80
100
90
110
Coil applied voltage,%V
5.-(1) Rate of change of pick-up and drop-out
voltage
(2 Form C single side stable)
120
5.-(2) Rate of change of pick-up and drop-out
voltage
(4 Form C single side stable)
120
Rated of change, %
100
Pick-up voltage
Rated of change, %
110
110
100
Pick-up voltage
90
Drop-out voltage
80
90
80
Drop-out voltage
–40 –20
0 20 40 60 80
Ambient temperature,
°C
–40 –20
0 20 40 60 80
Ambient temperature,
°C
6.-(1) Ambient temperature vs Max. applied
voltage
Tested sample:
NC2D-P-DC24 V (2 Form C slim single side stable)
6.-(2) Ambient temperature vs Max. applied
voltage
Tested sample:
NC2D-P-DC110 V (2 Form C slim single side stable),