R2M / RY2 / RUC
Industrial Electromagnetic Relays
●
Relays of general application
●
For plug-in sockets, 35 mm rail mount or on panel mounting
●
Cadmium-free contacts
●
R2M and RUC also for PCB and soldering connections
●
AC and DC coils available
E105728
R2M
DPDT
AC
AC1
DC1
AgNi*
250 V / 250 V
5V
5 A / 250 V AC
5 A / 24 V DC
5 mA
5A
1250 VA
0.3 W
≤
100 mΩ
1200 cycles/hour
36000 cycles/hour
6 ... 240 V
6 ... 110 V
≥
0.05 Un
see page
62
1.2 VA
0.9 W
250 V AC
2500 V
1.2 / 50 µs
II
3
2000 V AC type of insulation: basic
1000 V AC type of clearance: micro-disconnection
2000 V AC type of insulation: basic
≥
3 mm
≥
4 mm
AC: 8 ms / 7 ms; DC: 10 ms / 3 ms
> 2 x 10
5
; 5 A. 250 V AC
see Fig. 2.1
> 10
7
-
-
RY2
DPDT
AgNi*
250 V / 440 V
5V
12 A / 250 V AC
12 A / 30 V DC
5 mA
20 A
12A
3000 VA
0.3 W
≤
100 mΩ
1200 cycles/hour
18000 cycles/hour
6 ... 240 V
5 ... 220 V
AC:
≥
0.2 Un; DC:
≥
0.1 Un
see page
62
1.6 VA
0.9 W
250 V AC
4000 V
1.2 / 50 µs
III
3
RUC
DPDT. 3PDT. DPST. 3PST
AgNi*
400 V / 440 V
5V
16 A / 250 V AC or 10 A / 400 V AC
16 A / 24 V DC (see Fig. 3.3)
5 mA
40 A
16A
4000 VA
0.3 W
≤
100 mΩ
1200 cycles/hour
12000 cycles/hour
6 ... 240 V
6 ... 220 V
AC:
≥
0.15 Un; DC:
≥
0.1 Un
see page
62
2.8 VA 50 Hz; 2.5 VA 60
Hz
1.5 W; 1.7 W with contact gap
≥
3 mm
400 V AC
4000 V
1.2 / 50 µs
III
3
Contact Data
Number and type of contacts
Contact material
Rated / max. switching voltage
Min. switching voltage
Rated load
Min. switching current
Max. inrush current
Rated current
Max. breaking capacity
Min. breaking capacity
Contact resistance
Max. operating frequency
• at rated load
• no load
AC1
AC1
Coil Data
Rated voltage
50/60 Hz
AC
DC
Must release voltage
Operating range of supply voltage
Rated power consumption
AC
DC
Insulation
Insulation rated voltage
Rated surge voltage
Overvoltage category
Insulation pollution degree
Dielectric strength
between coil and contacts
• contact clearance
• pole - pole
Contact - coil distance
• clearance
• creepage
2500 V AC type of insulation: basic
2500 V AC type of insulation: basic
1000 V AC type of clearance: micro-disconnection 1500 V AC type of clearance: micro-disconnection
2500 V AC with contact gap
≥
3 mm.
type of clearance: full-disconnection
2500 V AC type of insulation: basic
2500 V AC type of insulation: basic
≥
2.6 mm
≥
4 mm
15 ms / 10 ms
> 10
5
; 12 A. 250 V AC
see Fig. 2.2
> 10
7
-
-
-
27.5 x 21.1 x 34.5 mm
35 g
-40...+70 °C
-40...+55 °C
≥
5 mm
≥
8 mm
20 ms / 15 ms
> 10
5
; 16 A. 250 V AC; > 10
5
; 10 A. 400 V AC
see Fig. 2.3
> 10
7
DPDT: 1/3 HP 120 V AC. single-phase motor
1/2 HP 240 V AC. single-phase motor
3PDT: 1/3 HP 120 V AC. single-phase motor
1/2 HP 240 V AC. single-phase motor
3PDT: 1/2 HP 240 V AC. three-phase motor
36.1 x 38.6 x 45.5 mm
80 g
-40...+85 °C
AC: -40...+55 °C 3PDT. 3PST (NO) /
16 A (+70 °C DPDT. DPST (NO) / 16 A)
DC: -40...+55 °C 3PDT. 3PST (NO) /
16 A (+70 °C 3PDT. 3PST (NO) /
10 A; DPDT. DPST (NO) / 16 A)
IP 00 PN-EN 60529
10 g
5 g 10...150
Hz
max. 270 °C
max. 5 s
General data
Operating / release time (typical values)
Electrical life
• resistive AC1
• cosφ
Mechanical life (cycles)
Motor load according to UL 508
Dimensions (L x W x H)
Weight
Ambient temperature
• storage
• operating
-
27.5 x 14 x 32.9 mm
22 g
-40...+70 °C
-40...+55 °C
Cover protection category
Shock resistance
Vibration resistance
Solder bath temperature
Soldering time
IP 40 PN-EN 60529
10 g
5 g 10...150
Hz
max. 270 °C
max. 5 s
IP 40 PN-EN 60529
10 g
5 g 15...150
Hz
-
-
* Other contact materials (eg. gold plated) available, contact Altech Corp.
58
Altech Corp.
®
• 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
DATA SUBJECT TO CHANGE WITHOUT NOTICE
R2M / RY2 / RUC
Industrial Electromagnetic Relays
R2M DPDT AC 50/60Hz & DC coil
Part Number
R2M-2012-23-1012
R2M-2012-23-1024
R2M-2012-23-1110
R2M-2012-23-5120
R2M-2012-23-5230
Coil Voltage
(V)
12
24
110
120
230
Coil Type
DC
DC
DC
AC 50/60Hz
AC 50/60Hz
Coil resistance
at 20 °C in
Ω
188
750
13480
6390
21470
Coil operating range
min. (at 20°C)
max. (at 55°C)
9.6
13.2
19.2
26.4
88.0
121.0
96.0
132.0
184.0
253.0
RY2 DPDT AC 50/60Hz & DC coil
Part Number
RY2-1012-26-1012
RY2-1012-26-1012-L
RY2-1012-26-1012-D
RY2-1012-26-1012-LD
RY2-1012-26-1024
RY2-1012-26-1024-L
RY2-1012-26-1024-D
RY2-1012-26-1024-LD
RY2-1012-26-1110
RY2-1012-26-1110-L
RY2-1012-26-1110-D
RY2-1012-26-1110-LD
RY2-1012-26-5024
RY2-1012-26-5024-L
RY2-1012-26-5024-D
RY2-1012-26-5024-LD
RY2-1012-26-5120
RY2-1012-26-5120-L
RY2-1012-26-5120-D
RY2-1012-26-5120-LD
RY2-1012-26-5230
RY2-1012-26-5230-L
RY2-1012-26-5230-D
RY2-1012-26-5230-LD
Coil Voltage
(V)
12
12
12
12
24
24
24
24
110
110
110
110
24
24
24
24
120
120
120
120
230
230
230
230
Coil Type
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
Coil resistance
at 20 °C in
Ω
160
160
160
160
640
640
640
640
13600
13600
13600
13600
158
158
158
158
3770
3770
3770
3770
16100
16100
16100
16100
Coil operating range
min. (at 20°C)
max. (at 55°C)
9.6
13.2
9.6
13.2
9.6
13.2
9.6
13.2
19.2
26.4
19.2
26.4
19.2
26.4
19.2
26.4
88.0
121.0
88.0
121.0
88.0
121.0
88.0
121.0
19.2
26.4
19.2
26.4
19.2
26.4
19.2
26.4
96.0
132.0
96.0
132.0
96.0
132.0
96.0
132.0
184.0
253.0
184.0
253.0
184.0
253.0
184.0
253.0
–
x
Options*
L
x
x
x
x
x
x
x
x
x
x
x
x
D
x
x
x
x
x
x
x
x
x
x
x
x
x
x
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
x
x
x
RUC DPDT AC 50/60Hz & DC coil
Coil Voltage
(V)
RUC-2012-26-1012
12
RUC-2012-26-1012-K
12
RUC-2012-26-1012-L
12
RUC-2012-26-1012-KL
12
RUC-2012-26-1024
24
RUC-2012-26-1024-K
24
RUC-2012-26-1024-L
24
RUC-2012-26-1024-KL
24
RUC-2012-26-1110
110
RUC-2012-26-1110-K
110
RUC-2012-26-1110-L
110
RUC-2012-26-1110-KL
110
RUC-2012-26-5120
120
RUC-2012-26-5120-K
120
RUC-2012-26-5120-L
120
RUC-2012-26-5120-KL
120
RUC-2012-26-5230
230
RUC-2012-26-5230-K
230
RUC-2012-26-5230-L
230
RUC-2012-26-5230-KL
230
–
= without additional features
K
= with test button without block function;
L
= with light indicator (LED)
D
= with surge suppression element (diode)
* other options available upon request
Part Number
Coil Type
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
DC
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
Coil resistance
at 20 °C in
Ω
110
110
110
110
430
430
430
430
9200
9200
9200
9200
1910
1910
1910
1910
7080
7080
7080
7080
Coil operating range
min. (at 20°C)
max. (at 55°C)
9.6
13.2
9.6
13.2
9.6
13.2
9.6
13.2
19.2
26.4
19.2
26.4
19.2
26.4
19.2
26.4
88.0
121.0
88.0
121.0
88.0
121.0
88.0
121.0
96.0
132.0
96.0
132.0
96.0
132.0
96.0
132.0
184.0
253.0z
184.0
253.0
184.0
253.0
184.0
253.0
–
x
Options*
K
x
x
x
x
x
x
x
x
x
x
L
x
x
x
x
x
x
x
x
x
x
x
x
AC
AC
AC
AC
AC
AC
AC
AC
x
x
BOLD
-
Regular stocked items.
62
Altech Corp.
®
• 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com