Digital Timer
Easy-to-see and Easy-to-operate
DIN 48 x 48 mm Digital Timer with
IP66/NEMA 4 Protection
Water- and dust-protected for severe environ-
ments.
Large, high-visibility LED displays with a height of
12 mm.
Simple setting with Increment and Decrement
Keys.
Conforms to EMC standards.
Six-language instruction manual provided.
H5CL
RC
Model
Without Finger Safe Terminal Cover
With Finger Safe Terminal Cover
---
H5CL-AD-500
---
---
H5CL-A
H5CL-AD
H5CL-AS
H5CL-ADS
Ordering Information
Outputs
Contact output
Transistor ou u
a s s o output
(Photocoupler)
(Ph t
l )
Supply voltage
100 to 240 VAC
12 to 24 VDC
100 to 240 VAC
12 to 24 VDC
Model Number Legend:
H5CL-A
1 2
3
1. Fixed
2. D: DC Supply Voltage
3. S: Transistor output
Accessories (Order Separately)
Name
Hard cover
Soft cover
Track Mounting/Front Connecting Socket (for AC
ac
ou
g/ o Co ec g Soc e ( o C
models only)
d l
l )
Back Connecting Socket (for AC models only)
ac Co ec g Soc e ( o C ode s o y)
Finger Safe Terminal Cover for DC models
Flush Mounting Adapter (see note 2)
Note:
---
Finger safe type
---
Finger safe type
Y92A-48
Y92A-48F1
P2CF-11
P2CF-11-E
P3GA-11
P3GA-11 with Y92A-48G (see note 1)
Y92A-48T
Y92F-30
Model
1. Y92A-48G is a finger safe terminal cover which is attached to the P3GA-11 Socket.
2. Supplied with each Unit.
1
H5CL
H5CL
Specifications
Item
Classification
Mounting
External connections
Enclosure ratings
Digits
Max. time settings
Display modes
Input signals
Input method
Operating modes
Reset system
Sensor waiting time
External power supply
Display
Memory backup
Mounting method
Approved standards
H5CL-Aj (AC models)
Digital timer
DIN track, surface, and flush mounting
(common)
Socket
4 digits (zero suppress method)
9.999 s (0.001-s unit), 99.99 s (0.01-s unit), 999.9 s (0.1-s unit), 9999 s (1-s unit),
99 min 59 s (1-s unit), 999.9 min (0.1-min unit), 99 h 59 min (1-min unit), 999.9 h (0.1-h unit)
Up (increment) and Down (decrement) (selectable)
Start, gate, reset, and key protection
No-voltage input: via NPN transistor or switching of contact
A (signal ON-delay), F (accumulative operation) (selectable)
Power reset (A (signal ON-delay) mode only), external, manual resets
216 ms typ., 250 ms max. (Control output is turned OFF and no input is accepted during
sensor waiting time.)
50 mA at 12 VDC (±10%)
---
7-segment LEDs (12 mm high, red LEDs for the present value, and 8 mm high, green LEDs for
the set value)
EEP-ROM (overwritten 200,000 times min.), which can store data for 20 years min.
DIN track mounting, surface mounting, and
flush mounting
UL 508, CSA C22.2 No.14
Conforms to EN61010-1
Flush mounting
Flush mounting
Screw terminals
H5CL-ADj (DC models)
Panel surface: IEC IP66 and NEMA Type 4 (indoors) when Y92S-29 rubber packing is used.
Ratings
Item
Rated supply voltage
Operating voltage range
Power consumption
Start, reset, gate inputs
Key protection input
Power reset
Control output
H5CL-Aj (AC models)
100 to 240 VAC, 50/60 Hz
85 to 264 VAC, 50/60 Hz
Approx. 10 VA
Response time: 1 s max.
Min. power opening time: 0.5 s (excluding F (accumulative operation) mode)
Contact output:
SPDT, 3 A at 250 VAC, resistive load (cosφ =1)
Min. applicable load: 10 mA at 5/24 VDC (P level, for reference value)
Transistor output: NPN open collector, 100 mA max. at 30 VDC max.,
residual voltage 1.5 VDC max.
H5CL-ADj (DC models)
12 to 24 VDC (permissible ripple: 20% (p-p) max.)
10.8 to 26.4 VDC
Approx. 3 W
Min. pulse width: 1 ms/20 ms (selectable, same for all three inputs)
2
H5CL
Characteristics
Item
Deviation of operating time and
setting error (including temperature
and voltage influences)
H5CL-Aj (AC models)
H5CL-ADj (DC models)
H5CL
Power start:
±0.01% ±0.05
s max. (see note 1)
Signal start:
±0.005% ±0.03
s max. (see note 1)
Signal start, at transistor output model:
±0.005% ±3
ms max. (see note 1 and 2)
If the set value is within the sensor waiting time (250 ms max.) in the case of power start, the
control output of the H5CL will not be turned ON until the sensor waiting time passes.
100 MΩ min. (at 500 VDC) (between current-carrying terminal and exposed
non-current-carrying metal parts, and between non-continuous contacts)
2,000 VAC, 50/60 Hz for 1 min (between
current-carrying terminal and exposed
non-current-carrying metal parts)
1,000 VAC, 50/60 Hz for 1 min (between
non-continuous contacts)
3.0 kV (between power terminals)
4.5 kV (between current-carrying terminal and
exposed non-current-carrying metal parts)
±1.5
kV (between power terminals)
±600
V (between input terminals),
square-wave noise by noise simulator (pulse
width: 100 ns/1
µs,
1-ns rise)
Destruction:
Malfunction:
Destruction:
Malfunction:
Destruction:
Malfunction:
Operating:
Storage:
Mechanical:
Electrical:
15 kV
8 kV
10 to 55 Hz, 0.75-mm single amplitude each in three directions
10 to 55 Hz, 0.5-mm single amplitude each in three directions
294 m/s
2
(30G) each in three directions
98 m/s
2
(10G) each in three directions
–10 to 55
°C
(–10 to 50
°C
if timers are mounted side by side) (with no icing)
–25 to 65
°C
(with no icing)
10,000,000 operations min.
100,000 operations min. (3 A at 250 VAC, resistive load)
1,000 VAC, 50/60 Hz for 1 min (between
current-carrying terminal and exposed
non-current-carrying metal parts, and
between non-continuous contacts)
1.0 kV (between power terminals)
1.5 kV (between current-carrying terminal and
exposed non-current-carrying metal parts)
±480
kV (between power terminals)
±600
V (between input terminals),
square-wave noise by noise simulator (pulse
width: 100 ns/1
µs,
1-ns rise)
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
EMC
Operating: 35% to 85%
(EMI):
Emission Enclosure:
Emission AC Mains:
(EMS):
Immunity ESD:
EN50081-2
EN55011 Group 1 class A
EN55011 Group 1 class A
EN50082-2
EN61000-4-2:4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference:
ENV50140: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Conducted Disturbance: ENV50141: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst:
EN61000-4-4:2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
Light gray (Munsell 5Y7/1)
Approx. 130 g
Approx. 110 g
Case color
Weight
Note:
1. The values are based on the set value.
2. The value is applied for a minimum pulse width of 1 ms.
3
H5CL
H5CL
Nomenclature
Indicator
1.
Present Value
Red LEDs with a character height of 12 mm
Note:
The decimal point will flash on the present value dur-
ing the timing operation in the following ranges:
0.1 to 999.9 min, 0 h 01 min to 99 h 59 min, and
0.1 to 999.9 h.
2.
Preset Value
Green LEDs with a character height of 8 mm
3.
Reset Indicator
(orange)
4.
Key Protection Indicator
(orange)
5.
Time Unit Display
(orange)
6.
Control Output Indicator
(orange)
Stick the enclosed label here.
1
6
3
7
2
5
8
9
Operation Key
7.
Reset (RST) Key
The RST Key initializes the present value and control output.
8.
Increment Keys (1 to 4)
Up Keys 1 to 4 increment the preset value.
9.
Decrement Keys (1 to 4)
Down Keys 1 to 4 decrement the preset value.
4
Operation
DIP Switch Setting
Pin no.
1, 2, 3
4
5
6
Note:
Time ranges
Display modes
Min. pulse width of inputs
Operating modes
Item
Up (Increment)
20 ms
A (signal ON-delay)
OFF
See table below.
Down (Decrement)
1 ms
F (accumulative operation)
ON
Set the DIP switch before installation and operation of the Unit. DIP switch setting changes are not effective while the power is on.
Time Ranges
1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Note:
ON
OFF
OFF
ON
ON
OFF
OFF
ON
2
ON
OFF
OFF
OFF
OFF
ON
ON
ON
3
0.001 to 9.999 s
0.01 to 99.99 s
0.1 to 999.9 s
1 to 9999 s
0 min 01 s to 99 min 59 s
0.1 to 999.9 min
0 h 01 min to 99 h 59 min
0.1 to 999.9 h
Time range
Switches 1 to 6 are all set to OFF before shipping.
(The same switch settings apply to AC and DC models)
Timer Control with Power Start
When using the H5CL with power start, short-circuit the start input and input 0-V terminals.
4
H5CL
Operating Modes
A Mode
Signal ON-delay
Power
Start
Gate
Reset
Control output
Set value
UP
0
Set value
DOWN
0
H5CL
Display
mode
F Mode
Accumulative Operation
Power
Start
Gate
Reset
Control output
Set value
UP
0
Set value
DOWN
0
Display
mode
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
H5CL-Aj
DIN Track/Surface/Flush Mounting
48
6
72.5
14.4
48
44.8 x 44.8
H5CL-ADj
Flush Mounting
(70)
48
6
64
48
44.8 x 44.8
5