GBU4005
THRU
GBU410
SINGLE PHASE 4.0 AMP BRIDGE RECTIFIERS
VOLTAGE RANGE
50 to 1000 Volts
CURRENT
FEATURES
* Ideal for printed circuit board
* Low forward voltage
.020R(TYP.)
.880(22.3)
.860(21.8)
.160(4.1)
.140(3.5)
4.0 Ampere
GBU
.140(3.56)
.130(3.30)
0.125(3.2)x45
CHAMFER
.740(18.8)
.720(18.3)
9
TYP.
* Low leakage current
* Polarity: marked on body
* Mounting position: Any
* Both normal and Pb free product are available:
* Normal:80~95%Sn,5~20%Pb
* Pb free:99 Sn above can meet Rohs enviroment substance
directive request
.310(7.90)
.290(7.40)
.085(2.16)
.065(1.65)
.075
(1.9)R
.080(2.03)
.060(1.52)
.100(2.54)
.085(2.16)
.050(1.27)
.040(1.02)
.190(4.83)
.210(5.33)
.710(18.0)
.690(17.5)
.085(2.16)
.075(1.90)
.080(2.03)
.065(1.65)
.022(0.56)
.018(0.46)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature uniess otherwies specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
.375"(9.5mm) Lead Length at Tc=50 C
Peak Forward Surge Current, 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Forward Voltage Drop per Bridge Element at 2.0A D.C.
Maximum DC Reverse Current
Ta=25 C
at Rated DC Blocking Voltage
Operating Temperature Range, Tj
Storage Temperature Range, TSTG
Ta=100 C
GBU4005
GBU401
GBU402
GBU404
GBU406
GBU408
GBU410
UNITS
50
35
50
100
70
100
200
140
200
400
280
400
4.0
150
1.0
5.0
500
-50 +150
-50 +150
600
420
600
800
560
800
1000
700
1000
V
V
V
A
A
V
uA
uA
C
C
RATING AND CHARACTERISTIC CURVES (GBU4005 THRU GBU410)
FIG.1-TYPICAL FORWARD CURRENT
DERATING CURVE
6.0
5.0
WITH HEATSINK
4.0
3.0
2.0
1.0
Single Phase
Half Wave 60Hz
Resistive Or Inductive Load
FIG.2-MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
PEAK FORWAARD SURGE CURRENT,(A)
250
AVERAGE FORWARD CURRENT,(A)
200
150
Tj=25 C
Single Half
Sine Wave
100
WITHOUT HEATSINK
JEDEC method
50
0
25
50
75
100 125
150
175
CASE TEMPERATURE ( C)
1
5
10
50
100
NUMBER OF CYCLES AT 60Hz
FIG.4-TYPICAL REVERSE CHARACTERISTICS
FIG.3-TYPICAL FORWARD CHARACTERISTICS
100
INSTANTANEOUS FOEWARD CURRENT ,(A)
10.0
100
CAPACITANCE,(pf)
10
TJ=25 C,F=1MHz
10
1.0
0.1
1.0
1.0
4.0
REVERSE VOLTAGE,VOL
TS
0.01
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
INSTANTANEOUS FOEWARD VOLTAGE ,VOL
TS
FIG.5-TYPICAL REVERSE
CHARACTERISTICS
1000
100
INSTANTANEOUS REVERSE CURRENT,(uA)
TJ=125C
TJ=100C
10
TJ=50C
1.0
TJ=25C
0.1
0
20
40
60
80
)
PERCENT OF RATED PEAK REVERSE VOLTAGE,(