cosmo
Features
1. Molded epoxy body.
2. Sealed construction permits automatic flow soldering
and cleaning.
3. High reliability relay.
4. Cost effective.
Reed Relay
G2A080000
Outside Dimension:Unit (
mm
)
Schematic : Top View
(+)
1
2
3
(-)
4
7
6
Coil Ratings
Parameter
Coil Resistance
Nominal Coil Voltage
Maximum Continuous Voltage
Must Operate
Must Release
Rated Current
(AT 20℃)
Rating
700
8
12
5.6
0.8
11.4
Unit
Ω(±10%)
VDC
VDC
VDC
VDC
mA
Electrical Characteristics
Parameter
Contact Resistance
Operate Time
Bounce Time
Release Time
Insulation Resistance (100VDC)
Power
Switching Voltage
Switching Current
Carry Current
Breakdown Voltage (Across Open Contact)
(Between Coil & Contact)
Life Expectancy (Signal Level)
Operate Temp
Storage Temp
Resonant Frequency
Vibration (10~200Hz)
Minimum Permissible Load
Rating
100
0.5
0.5
0.2
10
11
10
200
0.5
1.0
250
1500
10
8
-40~85
-50~125
3.5
20
100
Unit
mΩ(max)
ms(max)
ms(max)
ms(max)
Ω(min)
VA(max)
VDC(max)
A(max)
A(max)
VDC(min)
VDC(max)
℃
℃
KHz
g(max)
mVDC 10uA
C
○
2005-2006 COSMO
ELECTRONICS CORPORATION
http://www.cosmo-ic.com