Vibration alarm circuit

Source: InternetPublisher:Lemontree Keywords: Alarm circuit piezoelectric ceramics time base circuit Updated: 2021/02/03

42.<strong>Vibration</strong><strong>Alarm circuit</strong>.gif

Working principle of the circuit: This circuit uses an integrated circuit ICM7556, two piezoelectric
ceramics X1 and X2 and several passive electronic components to form a mechanical vibration alarm, which can
produce an alarm sound for 1 minute. As long as mechanical vibration is applied to the piezoelectric ceramic X1 , a voltage will be generated on the 10 MΩ resistor at pin 6 of IC1 (A), triggering the time base circuit 7556, causing the piezoelectric ceramic X2 to sound an alarm. The second time base circuit IC1(B) generates a self-excited signal modulated by a low frequency of 5 Hz.