The magnetic flap level gauge is developed based on the buoyancy principle and magnetic coupling. The basic principle is that when the liquid level in the measured container rises and falls, the magnetic float in the body tube of the level gauge also rises and falls. The permanent magnet in the float is transmitted to the magnetic flip column indicator through magnetic coupling, driving the red and white flip columns to flip. When the liquid level rises, the flip column changes from white to red, and when the liquid level drops, the flip column changes from red to white. The red and white junction of the indicator is the actual height of the liquid level inside the container, thereby achieving a clear indication of the liquid level. The
magnetic flap level gauge can be highly sealed, leak-proof and suitable for high temperature, high pressure and corrosion-resistant occasions. It is more superior to high temperature, high pressure, toxic, harmful and highly corrosive media. In direct contact with the medium, the float sealing requirements must be strict, and viscous media cannot be measured. Magnetic materials such as demagnetization can easily cause the level gauge to not work properly and the flap is easy to get stuck, resulting in the inability to transmit indication remotely. Magnetic materials such as demagnetization can easily cause the level gauge to not work properly.
When many people mention the magnetic flap level gauge, they will immediately think of its own safety and reliability. It does not need to face certain harmful toxic substances directly in person, nor does it need on-site contact. It can monitor and record in real time. No wonder it is so popular. Such an excellent magnetic flap level gauge is of course indispensable in industry. At the same time, it has a large measurement range and can ensure that there is no blind spot in the whole process measurement, which is beyond the reach of many devices. Therefore, many high-temperature, high-pressure, flammable and explosive medium liquids are often measured with magnetic flap level gauges. The most notable feature of
the magnetic flap level gauge is that the liquid medium is completely isolated from the indicator, so that its measurement can be safely monitored under any circumstances. At the same time, the magnetic flap level gauge is reliable and durable enough, and can also realize the alarm of the upper and lower limits of the liquid level, and provide remote control and recording. It can be used for medium level detection of various towers, tanks, spherical containers, boilers and other equipment. It is more appropriate to use it as a detector for some highly corrosive, toxic and harmful substances. In addition, the readings designed by itself are relatively intuitive, which makes the magnetic flap level gauge very suitable for various liquid level detection tasks.
When the magnetic flap remote level gauge is equipped with a remote transmission supporting instrument, the following points must be met:
(1) The remote transmission supporting instrument should be close to the main pipe of the level gauge and fixed with a stainless steel clamp (iron is prohibited);
(2) The sensing surface on the remote transmission supporting instrument should face and be close to the main pipe;
(3) The zero position of the remote transmission supporting instrument should be on the same horizontal line as the zero position indication of the level gauge;
(4) The connection between the remote transmission supporting instrument and the display instrument or industrial computer is best laid in a protective tube or with a shielded two-core cable;
(5) After the wiring hole of the junction box is laid, it is required to be well sealed to prevent rainwater, moisture, etc. from invading and causing the remote transmission supporting instrument to malfunction. The junction box should be covered in time after maintenance or commissioning.
Reference address:Magnetic flap level gauge measuring high temperature, high pressure, flammable and explosive media and supporting remote transmission precautions
magnetic flap level gauge can be highly sealed, leak-proof and suitable for high temperature, high pressure and corrosion-resistant occasions. It is more superior to high temperature, high pressure, toxic, harmful and highly corrosive media. In direct contact with the medium, the float sealing requirements must be strict, and viscous media cannot be measured. Magnetic materials such as demagnetization can easily cause the level gauge to not work properly and the flap is easy to get stuck, resulting in the inability to transmit indication remotely. Magnetic materials such as demagnetization can easily cause the level gauge to not work properly.
When many people mention the magnetic flap level gauge, they will immediately think of its own safety and reliability. It does not need to face certain harmful toxic substances directly in person, nor does it need on-site contact. It can monitor and record in real time. No wonder it is so popular. Such an excellent magnetic flap level gauge is of course indispensable in industry. At the same time, it has a large measurement range and can ensure that there is no blind spot in the whole process measurement, which is beyond the reach of many devices. Therefore, many high-temperature, high-pressure, flammable and explosive medium liquids are often measured with magnetic flap level gauges. The most notable feature of
the magnetic flap level gauge is that the liquid medium is completely isolated from the indicator, so that its measurement can be safely monitored under any circumstances. At the same time, the magnetic flap level gauge is reliable and durable enough, and can also realize the alarm of the upper and lower limits of the liquid level, and provide remote control and recording. It can be used for medium level detection of various towers, tanks, spherical containers, boilers and other equipment. It is more appropriate to use it as a detector for some highly corrosive, toxic and harmful substances. In addition, the readings designed by itself are relatively intuitive, which makes the magnetic flap level gauge very suitable for various liquid level detection tasks.
When the magnetic flap remote level gauge is equipped with a remote transmission supporting instrument, the following points must be met:
(1) The remote transmission supporting instrument should be close to the main pipe of the level gauge and fixed with a stainless steel clamp (iron is prohibited);
(2) The sensing surface on the remote transmission supporting instrument should face and be close to the main pipe;
(3) The zero position of the remote transmission supporting instrument should be on the same horizontal line as the zero position indication of the level gauge;
(4) The connection between the remote transmission supporting instrument and the display instrument or industrial computer is best laid in a protective tube or with a shielded two-core cable;
(5) After the wiring hole of the junction box is laid, it is required to be well sealed to prevent rainwater, moisture, etc. from invading and causing the remote transmission supporting instrument to malfunction. The junction box should be covered in time after maintenance or commissioning.
Previous article:Reasons for the decrease of accuracy in the measurement process of turbine flowmeter and corresponding solutions
Next article:Briefly describe the application of magnetic flap level gauge in level measurement of oil tank storage volume
- Popular Resources
- Popular amplifiers
- Chip Manufacturing: A Practical Tutorial on Semiconductor Process Technology (Sixth Edition)
- Design of an Embedded Control System for an Artificial Diamond Press
- Introducing a low-cost, simple design method for designing a digital barometer system using a pressure sensor.pdf
- MICRF112 pdf datasheet (QwikRadio®UHF ASK/FSK Transmitter)
Latest Test Measurement Articles
- New IsoVu™ Isolated Current Probes: Bringing a New Dimension to Current Measurements
- Modern manufacturing strategies drive continuous improvement in ICT online testing
- Methods for Correlation of Contact and Non-Contact Measurements
- Keysight Technologies Helps Samsung Electronics Successfully Validate FiRa® 2.0 Safe Distance Measurement Test Case
- From probes to power supplies, Tektronix is leading the way in comprehensive innovation in power electronics testing
- Seizing the Opportunities in the Chinese Application Market: NI's Challenges and Answers
- Tektronix Launches Breakthrough Power Measurement Tools to Accelerate Innovation as Global Electrification Accelerates
- Not all oscilloscopes are created equal: Why ADCs and low noise floor matter
- Enable TekHSI high-speed interface function to accelerate the remote transmission of waveform data
MoreSelected Circuit Diagrams
MorePopular Articles
- Intel promotes AI with multi-dimensional efforts in technology, application, and ecology
- ChinaJoy Qualcomm Snapdragon Theme Pavilion takes you to experience the new changes in digital entertainment in the 5G era
- Infineon's latest generation IGBT technology platform enables precise control of speed and position
- Two test methods for LED lighting life
- Don't Let Lightning Induced Surges Scare You
- Application of brushless motor controller ML4425/4426
- Easy identification of LED power supply quality
- World's first integrated photovoltaic solar system completed in Israel
- Sliding window mean filter for avr microcontroller AD conversion
- What does call mean in the detailed explanation of ABB robot programming instructions?
MoreDaily News
- STMicroelectronics discloses its 2027-2028 financial model and path to achieve its 2030 goals
- 2024 China Automotive Charging and Battery Swapping Ecosystem Conference held in Taiyuan
- State-owned enterprises team up to invest in solid-state battery giant
- The evolution of electronic and electrical architecture is accelerating
- The first! National Automotive Chip Quality Inspection Center established
- BYD releases self-developed automotive chip using 4nm process, with a running score of up to 1.15 million
- GEODNET launches GEO-PULSE, a car GPS navigation device
- Should Chinese car companies develop their own high-computing chips?
- Infineon and Siemens combine embedded automotive software platform with microcontrollers to provide the necessary functions for next-generation SDVs
- Continental launches invisible biometric sensor display to monitor passengers' vital signs
Guess you like
- [Hua Diao Experience] 07 Building a Xingkong board development environment for VSCode programming
- 【GD32307E-START】Solve the last problem + routine test
- Added multiple ST sensor drivers in MakeCode
- Selection of power device heat sink
- LabView Note 4: Temperature Monitoring System Based on LabView Password Login
- Introduction to IC chip types
- Detailed list and contact information of domestic IC design companies in Shanghai
- [15th Anniversary] Wireless Serial Port PCB Arrived
- The command configurations in the manual are all expressed in hexadecimal. How should they be used in the code?
- I just used MPLAB X IDE, and I get a compilation error. I don't understand why.