Article count:1333 Read by:1940015

Account Entry

[Shishuo Core Products] A low-noise instrumentation amplifier with nanovolt-level sensitivity is constructed like this!

Latest update time:2022-11-25
    Reads:


There are many design challenges associated with building a voltage measurement system with nanovolt-level sensitivity. Today's better op amps (such as the low-noise AD797) can achieve sub-1nV/Hz noise performance (1 kHz), but low-frequency noise limits The achievable noise performance is approximately 50 nV pp (in the 0.1 Hz to 10 Hz frequency band).


Oversampling and averaging can reduce the rms contribution of broadband noise, but at the expense of higher data rates and higher power consumption, but oversampling will not reduce the noise spectral density, and it has no effect on noise in the 1/f region. Influence. In addition, in order to avoid noise contribution from the rear stage, a larger front-end gain is required, thereby reducing the system bandwidth. Without isolation, all ground bounce or interference will show up at the output and potentially ruin the low internal noise situation of the amplifier and its input signal. A well-performing low-noise instrumentation amplifier simplifies design and reduces residual errors caused by common-mode voltage, power supply fluctuations, and temperature drift.


The AD8428 low-noise instrumentation amplifier provides an accurate gain of 2000 and has all the features necessary to solve these problems. The AD8428 features 5 ppm/°C maximum gain drift, 0.3 μV/°C maximum offset voltage drift, 140 dB minimum CMRR to 60 Hz (120 dB minimum to 50 kHz), 130 dB minimum PSRR, and 3.5 MHz bandwidth for low power applications. Flat measurement system. Notable is the device's 1.3 nV/Hz voltage noise (1 kHz) and 40 nV pp noise (0.1 Hz to 10 Hz) performance, resulting in high signal-to-noise ratio at very small signals. Two additional pins allow designers to change gain or add filters to reduce noise bandwidth. These filter pins also provide a unique method of reducing noise.


Using multiple AD8428
Instrumentation amplifiers reduce system noise


Figure 1 shows a circuit configuration that further reduces system noise. The input and filter pins of the four AD8428s are short-circuited to each other to reduce the noise to half of the original value. The output of either instrumentation amplifier can be used to maintain low output impedance. This circuit can be expanded to reduce noise by a factor of the square root of the number of amplifiers used.


Figure 1. Noise reduction circuit using four AD8428 instrumentation amplifiers.


Each AD8428 produces a typical spectral noise referred to input (RTI) of 1.3 nV/Hz, which is uncorrelated with the noise produced by the other amplifiers. Uncorrelated noise sources add to the filter pins in a root sum of squares (RSS) manner. On the other hand, the input signal is positively correlated. Each AD8428 generates the same voltage at the filter pin in response to the signal, so connecting multiple AD8428s does not change the voltage and the gain remains at 2000.


Noise Analysis


Analysis of a simplified version of the circuit in Figure 2 shows that connecting two AD8428s in this way reduces the noise by a factor of two. The noise of each AD8428 can be modeled on the +IN pin. To determine the total noise, you can connect the inputs to ground and use superposition to combine the noise sources.


Noise source en1 is amplified by a differential gain of 200 and reaches the output of preamplifier A1. For the purpose of this part of the analysis, the output of preamplifier A2 is noise-free when the input is connected to ground. The 6 kΩ/6 kΩ resistor divider between each output of preamplifier A1 and the corresponding output of preamplifier A2 can be replaced by a Thevenin equivalent circuit: half the noise voltage at the output of preamplifier A1 and a 3 kΩ Series resistance. This part is the mechanism for reducing noise. A complete nodal analysis shows that the output voltage in response to en1 is 1000 × en1 . Because of the symmetry, the output voltage in response to the noise voltage en2 is 1000 × e n2 . Both e n1 and e n2 amplitudes are equal to e n and will add up as RSS, resulting in a total output noise of 1414 × e n .


Figure 2. Simplified circuit model for noise analysis


In order to translate this back to the input, the gain must be verified. Assume that a differential signal VIN is applied between +INPUT and –INPUT. The differential voltage at the output of the first stage of A1 is equal to VIN × 200. The same voltage appears at the output of preamplifier A2, so no divided signal goes into the 6 kΩ/6 kΩ divider, and node analysis shows that the output is VIN × 2000. Therefore, the total voltage noise RTI is en × 1414/2000, which is equivalent to en / 2. Using the AD8428's typical noise density of 1.3 nV/Hz, the resulting noise density of the two amplifier configuration is approximately 0.92 nV/Hz.


With the additional amplifier, the impedance at the filter pins changes, further reducing noise. For example, using four AD8428s as shown in Figure 1, the 6 kΩ resistor from the preamplifier output to the filter pin would be followed by three 6 kΩ resistors to the output of each noiseless preamplifier. This effectively creates a 6 kΩ/2 kΩ resistor divider, dividing the noise by four. Therefore, as predicted, the total noise of the four amplifiers is equal to en/2.


Making Noise vs. Power Consumption Tradeoffs


The main trade-off is power consumption versus noise. The AD8428 has extremely high noise-to-power efficiency with an input noise density of 1.3 nV/Hz (6.8 mA maximum supply current). For comparison, consider the low-noise AD797 op amp - this device requires 10.5 mA maximum supply current to achieve 0.9 nV/Hz. A discrete G = 2000 low-noise instrumentation amplifier built with two AD797 op amps and a low-power difference amplifier requires more than 21 mA to achieve 1.45 nV/Hz contributed by the two op amps and a 30.15 Ω resistor. Noise RTI performance.

In addition to the power supply considerations that many amplifiers use when connected in parallel, designers must also consider the thermal environment. A single AD8428 operating from a ±5 V supply will increase the temperature by approximately 8°C due to internal power dissipation. If many devices are placed close to each other or in a closed space, they will conduct heat to each other, and thermal management technology needs to be considered.


SPICE simulation


SPICE circuit simulation, while not a substitute for prototyping, is useful as a first step in validating such circuit ideas. To verify this circuit, you can use the ADIsimPE simulator and the AD8428 SPICE macromodel to simulate the circuit performance when two devices are connected in parallel. The simulation results in Figure 3 show that the circuit behaves as expected: a gain of 2000 and a 30% noise reduction.


Figure 3. SPICE simulation results


Measurement results


Measure the complete circuit of four AD8428s on the bench. The measured RTI noise spectral density is 0.7 nV/Hz (1 kHz) with 25 nV pp from 0.1 Hz to 10 Hz. This is lower noise than many nanovolt voltmeters. The measured noise spectrum and peak-to-peak noise are shown in Figure 4 and Figure 5 respectively.


Figure 4. Measured voltage noise spectrum for the circuit in Figure 1.


Figure 5. Measured 0.1 Hz to 10 Hz RTI noise for the circuit in Figure 1


in conclusion


Nanovolt sensitivity targets are very difficult to achieve and present many design challenges. For systems requiring low noise and high gain, the AD8428 instrumentation amplifier has the characteristics required to enable high-performance designs. Additionally, the device's unique configuration allows this unusual circuit to be added to its nanovolt toolbox.





Original text reproduced from Analog Devices




Shijian also has his own video account~

Click to watch and learn more about Shijian



Scan the code to buy now


Scan the QR code now for details




About Shijian

The leading authorized component agent in the Asia-Pacific region


Excelpoint is a complete solution provider, providing high-quality components and engineering design to Asian electronics manufacturers, including original equipment manufacturers (OEMs), original design manufacturers (ODMs) and electronic manufacturing service providers (EMS). and supply chain management services.


Shijian is headquartered in Singapore and has a history of more than 30 years. Shijian China is headquartered in Hong Kong and currently has more than ten branches and offices in China, covering major large and medium-sized cities in China. With a professional R&D team, top-notch on-site application support and rich market experience, Shijian enjoys a leading position in the Chinese industry.






Click "Read the original text" to contact us
↓↓↓


Latest articles about

 
EEWorld WeChat Subscription

 
EEWorld WeChat Service Number

 
AutoDevelopers

About Us Customer Service Contact Information Datasheet Sitemap LatestNews

Room 1530, Zhongguancun MOOC Times Building,Block B, 18 Zhongguancun Street, Haidian District,Beijing, China Tel:(010)82350740 Postcode:100190

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号